Flintweigh ii software installation, Software version, Installation of flintweigh ii – Flintec II IPC User Manual

Page 17: Flintweigh ii files

Advertising
background image

FlintWeigh II IPC Technical Manual, Rev. 1.06 November 2011

Page 17 of 36

6.

FlintWeigh II Software Installation

The FlintWeigh II software displays the continuously measured weight value of the weighing system controller
within a graphical window in a legal for trade quality.

FlintWeigh II also provides an OLE interface. External programmes can access the data and information within
FlintWeigh II by using OLE functions. All windows and control buttons are part of the OLE interface.

By configuring two digital outputs and one digital input it is possible to implement a simple limit monitoring or
traffic light control.

6.1. Software Version

The software version is defined as follows:

NWxyF.exe

with x = Main version no.
and y = Revision no.

e.g.: NW11F.exe Main version no. 1, Rev. no. 1

6.2. Installation of FlintWeigh II

It is not required to install the FlintWeigh II software in the conventional way. Just copy the files "NW11F.exe"
and "nxWeigh.dll" to a directory of your choice. In this directory further configuration files will be created (see
below).

Hint: Your profile as a Windows user requires writing preferences for this installation directory.

When started for the first time FlintWeigh II should start with the language setting "English" (see chapter 8.2).

6.3. FlintWeigh II Files

In the FlintWeigh II software directory you can find the following files (some files may be hidden or protected
and therefore not visible):

NW11F.EXE

FlintWeigh II main programme; can be used directly (EXE file) as weight display or for
service and calibration purposes. In weighing mode the main programme can communicate
to application programmes via its integrated OLE interface. If the OLE interface is in use the
FlintWeigh II software automatically starts in the weighing mode.

NW10.KEY

This file will be created during the commissioning. It contains non-approved parameters and
settings like COM port, baud rate, remote display, language, filter settings, zero tracking,
etc.

NW10.INI

This file will be created during the commissioning. It contains the path information to the
storage location of the alibi data.

NW10.LIM

This file will be created during the commissioning. It contains the manual settings of the
digital outputs (setpoints).

NW10xx.CFG

This file will be created during the commissioning. For diagnosis purposes it contains copies
of the calibration data, which are stored in the approved memory of the weighing system
controller.


Following files may be located in the FlintWeigh II software directory or somewhere else (see data memory

Server):

NW10.CNT

Record counter (for multi scale systems), protected by CRC16 checksum

NWmmjj.MEM

Alibi memory files, divided by month (mm = month, yy = year), protected by CRC16
checksum