Flintec II IPC User Manual

Page 34

Advertising
background image

FlintWeigh II IPC Technical Manual, Rev. 1.06 November 2011

Page 34 of 36


Function

Description

Regist

Register the current weight value – Format 1

Return value

Value range

Format: string, 16 digits:

“rrrrrr nnnnnnn dd w” with

rrrrrr

Record no., 6 digits

000001, 000002, 000003...

nnnnnnn

Weight value including
decimal point, 7 digits

0...800 000

dd

Weight unit, 2 digits

g, kg, t, lb

w

Scale no., 1 digit

1 (scale 1); 2 (scale 2); 3 (dual scale)

Hint: Unused places within the weight value will be filled with spaces.

Attention: In legal for trade operation an entry to the alibi memory will be created and the
record counter will be incremented by one.

If a recording is not possible, a 2-digit error code will be notified:

E1

Scale in motion

E4

No zero crossing

E2

Weight value

0

E5

Open input (tilt)

E3

Gros weight < minimum load

E6

Overload, etc.

Regist2

Register the current weight value – Format 2

Return value

Value range

Format: string, 30 digits:

“w_rrrrrr_nnnnnnn_kk_tttt tt_dd“ with

w

Scale no., 1 digit

1 ( ca e 1); 2 (scale 2); 3 (dual scale)

rrrrrr

Record no., 6 digits

000001, 000002, 000003...

nnnnnnn

Weight value including
decimal point, 7 digits

0...800 000

kk

Tare indication

„ “ (no tare); „ T“ (normal tare);
„PT“ (manual tare entry)

ttttttt

Tare value including
decimal point, 7 digits

0...800 000

dd

Weight unit, 2 digits

g, kg, t, lb

Hint: Unused places within the weight value will be filled with spaces.

Attention: In legal for trade operation an entry to the alibi memory will be created and the
record counter will be incremented by one.

If a recording is not possible, a 2-digit error code will be notified:

E1

Scale in motion

E4

No zero crossing

E2

Weight value

0

E5

Open input (tilt)

E3

Gros weight < minimum load

E6

Overload, etc.

Param(w)

Read scale parameters

Parameter

Type

Use

w

Integer

w = 1 (scale 1); w = 2 (scale 2); w = 3 (dual scale)

Return value

Value range

Format: string, 17 digits:

"w_t_z1_z2_z3_k_dd" with

w

Scale no., 1 digit

1 (scale 1); 2 (scale 2); 3 (dual scale)

t

Scale type, 1 digit

1 (single-interval), 2 (multi-range), 3 (multi-interval)

z1

Scale interval 1, 2 digits

01, 02, 05, 10, 20, 50

z2

Scale interval 2, 2 digits

02, 05, 10, 20, 50 (at single-interval: 01)

Z3

Scale interval 3, 2 digits

05, 10, 20, 50 (at single-interval: 01)

k

Decimal places, 1 digit

1, 2, 3, 4, 5

dd

Weight unit, 2 digits

g, kg, t, lb

Advertising