Sealing details with sticker, Descriptive plate – Flintec II IPC User Manual
Page 12

FlintWeigh II IPC Technical Manual, Rev. 1.06 November 2011
Page 12 of 36
Step 5:
Put the supplied wire strap from the upside through one of the holes of the controller
card. Lead the wire strap on the bottom side to a second hole of the controller card
and from there back to the upside. Tighten the wire strap by hand.
Step 6:
Reinstall the weighing system controller into the weighing terminal. Fix the interlock
of the PCI plug-in card. Close the enclosure of the weighing terminal properly.
4.6. Sealing Details with Sticker
The legal for trade operation requires a sealing of the plug connectors. The following figure shows a possible
positioning of stickers.
Fig 4.6: Sealing details with sticker
4.7. Descriptive Plate
The descriptive plate has to be placed on the weighing terminal’s enclosure. It must coincide with the digital
descriptive plate within the FlintWeigh II software.
The descriptive plate supplies following information:
►
Owner and number of the EC type approval
►
Version no. of the software incl. revision no./
check sum
►
Serial no. of the built-in weighing system controller
►
Type and serial no of the LDUs
►
Year of manufacture
►
Traceable access counter (TAC)
►
Metrological symbol “M”
►
Interval, min.load and max. load of the scale
Fig. 4.7: Descriptive plate of the weighing terminal
Hint: You can find a template for the scale’s descriptive plate in RTF format on the Flintec CD-ROM.
Sticker