4.4 Changing the Analogue Output Type
FAA-26 checks the T and R pins connection and sets its analog output according to
the table below at power on. To change the analog output mode short circuit or open
circuit T and R pins of the instrument before power on the instrument.
Analogue Output Type
T and R pins
V/I LED
Current output
Open circuited
On
Voltage output
Short circuited
Flash
After setting your analog output type go to the next step.
4.5 Commissioning
Survey the following steps before energizing the instrument.
Mechanical installation, grounding, load cell connection and power supply
connection.
The T and R pins on the instrument shall be defined the analog output type
The analog output cabling should be done for the same analog output type.
The adjustment rotary switches shall be at
“ 0 “ position at power on.