4.4 Changing the Analogue Output Type

FAA-26 checks the T and R pins connection and sets its analog output according to
the table below at power on. To change the analog output mode short circuit or open
circuit T and R pins of the instrument before power on the instrument.

Analogue Output Type

T and R pins

V/I LED

Current output

Open circuited

On

Voltage output

Short circuited

Flash



After setting your analog output type go to the next step.


4.5 Commissioning

Survey the following steps before energizing the instrument.

Mechanical installation, grounding, load cell connection and power supply

connection.

The T and R pins on the instrument shall be defined the analog output type

as seen in

Chapter 4.4

at power on.

The analog output cabling should be done for the same analog output type.

The adjustment rotary switches shall be at

0 “ position at power on.