Features – Flintec FAA-26 User Manual

Page 6

Advertising
background image

FAA-26, Technical Manual, Rev. 1.1, June 2014

Page 5 / 13

Features

Minimized zero and span drifts because of its microcontroller technology and

high accurate, very low temperature drift 24 bits ADC and 16 bits DAC
converters.

Long time stability and low temperature drifts eliminates the frequent

readjustment period.

Digital adaptive anti-vibration filters to minimize environmental vibrations.

Very easy and user friendly digital adjustment via rotary switches located on

the front of the instrument.

All instruments are adjusted to 0

– 10 V and to 4 – 20 mA analog output

ranges for 0

– 10 mV load cell signal range in production as default. (only for

2mV/V load cells)

Calibration at PLC does not require readjustment after changing instrument

because of matching in the production.

TECHNICAL SPECIFICATIONS

Analogue input range

0 mV to 20 mV

Minimum input range

< 1 mV

Linearity

< % 0.01

Temperature drift

< 0.007 % FSR / ºC

Converters

24 bit Delta-Sigma ratiometric ADC with integral analog and
digital filters; 16 bit very low drift DAC

Internal resolutions

16 000 000 counts ADC

External resolution

Analogue output changes up to 65000 steps

Calibration

With rotary switches in the front with any test load.
Preadjusted and matched instrument for calibration at PLC

Analogue outputs

Current output for 4-20 mA ;
Voltage output for 0-10 VDC.

Max. cable length

300 meter

Max. load resistance
(current output)

500 Ω

Load cell excitation

5 VDC

Number of Load Cells

Up to 4 units of 350

or 12 units of 1100

(min. 85

)

Power supply

12 to 28 VDC 0.2 A

Operation Temperature Between -10 °C and +45 °C at 85% RH max, non-condensing

EMC Immunity

Class E2

Enclosure

Polyamide, for DIN-rail mount, IP20

Dimensions

Front Width:22,5 mm, Front Length: 99 mm , Height:114,5mm,

Advertising