4.2 Load Cell Connection

The load cell wiring should be made carefully before energizing to avoid damages to
the instrument and load cells. The input resistance of the load cells that you want to
connect should be more than 85 Ω.

Pin Name

Load Cell Cable

+Ex

+ Excitation

-Ex

- Excitation

+Si

+ Signal

-Si

- Signal

Shield

4.3 Analogue Output Connection

Only one of the analog output types can be used at the same time and has to be
selected in the setup. Install the analog output measuring instrument for adjustment,
if need be.

Pin Name

Definition

I

Current Output

V

Voltage Output

G

GND

Shield