FAA-26, Technical Manual, Rev. 1.1, June 2014

Page 12 / 13

6. Operation

There are 3 LEDs and 2 adjustment rotary switches on the front panel of FAA-26.
The rotary switches should be at

0“ positions for operation.


In operation rotary switch positions, T and R pins connection, and LEDs
announces are;

Analogue

Output Type

Gain Adj.

Sw. position

Zero Adj.

Sw. position

T and R pins

V/I LED

( after power

on )

Current

Open
circuited

On

Voltage

Short
circuited

Flash


Refer to

chapter 8

in case of the Err LED turns on.


The analogue output signal also gives information about the status of the system and

the weighing process to inform PLC as;


Condition

Current

output

Voltage

output

Operation

X

X

Programming

X

X

The weight is higher than the range
( Over signal to PLC )

24 mA

11 V

The weight is under than the zero range
(Under signal to PLC )

0 mA

-4.0 V

“Error” signal to PLC

0 mA

0 V

“ADC is out of operating range” error to PLC

24 mA

11 V