FAA-26, Technical Manual, Rev. 1.1, June 2014

Page 4 / 13

3.

Front View, Features and Specifications

Microcontroller based analog load cell transmitter FAA-26 has very high accuracy
and long term stability with its high tech design.

This high accurate instrument gives the system designers a lot of advantages to
increase the system reliability and to reduce the installation and service times. All
instrument

s’ analog outputs are matched in the production to perform calibration at

PLC and for changing the instrument without recalibration in service if adjustment is
done in PLC.

There are 2

rotary switches and annunciator LED’s in front of the instrument.

The upper rotary switch adjusts

unloaded scale’s analog output level (zero

adjustment) and the lower rotary switch adjusts gain of the instrument. The front view
and pin descriptions of FAA-26 is shown below.

Pin

Name

Definition

LOAD CELL CONNECTION

- Ex

- Excitation

+ Ex

+ Excitation

- Si

- Signal

+ Si

+ Signal

ANALOGUE OUTPUT

I

4 - 20mA output

V

0 - 10V output

G

GND

Shield and Protective ground

ANALOG OUTPUT RANGE

T

Refer to chapter 4.4

R

Refer to chapter 4.4

G

Ground

NC

Not used

NC

Not used

NC

Not used

POWER SUPPLY

24V

+24VDC

0V

0VDC

FAA-26