GTCO UltraSlate Commands User Manual

GTCO Computer hardware

Advertising
background image

Power Up Default
9600 8 no parity 1 stop bit
Format #23
Run mode
1000 lpi
100 pps

Operating Modes

Run Mode: Digitizer outputs coordinate data continuously.

Increment Mode Filter: Puts a movement filter on data in any mode. The transducer must
move N counts before the data can be sent. Then both axis data are updated. If out of
proximity data is enabled in increment mode, one data point may be sent on leaving
proximity.

Prompt Mode Modifier:
Places the additional restriction on data transmission that the host
must transmit a prompt character to the tablet for each data point output. All other rules
of normal operation apply. The prompt character is “?”. Prompting is a feature, which
operates in conjunction with any of the above standard modes.

Send Data Out of Proximity Mode Modifier:
If this flag is set, coordinate data will be sent
when it meets the output conditions in or out of the active area. Cordless units may not
respond to button information until cursor is close to tablet.

NOTE: This command should be sent after the mode commands.

Send Data in Margin:
If this flag is set, coordinate data point will be sent when it meets the
output conditions in the active area or when in margins.

NOTE:
Margins on some of the tablets are very small and are larger leaving the tablet than
coming in.