3 Cable Connection

Multiple-function combination cable consists of network cable, audio/video terminal, and relay
in/out terminal. Please refer to the following instruction labels for further reference.
RS485, audio/video interfaces are shown below:

Name

Function

A

485-A. It is to control dome built-in PTZ.

B

485-B. It is to control dome built-in PTZ.

485

GND Ground.

GND Ground.

VIDE
O

OUT

Video output

AC24V

24V power port. Connect to the power cable.

EARTH

Ground port.

AC24V

24V power port. Connect to power cable.

1. 。Please refer to the label instruction for the alarm connection information of the multiple-
function combination cable.

2. Relay in/out interfaces are shown below:

Name

Function

Alarm out:1-2

a) Two alarm output channels. When there is an alarm

from current channel, system activates relay or not.

b) Alarm output relay default setup is NO. You can use

the jump-cap near the power board relay to set.

c) NO:Normal open alarm output.

d) NC:Normal close alarm output.

GND

Alarm input ground end.

Alarm in:1-7

e) Seven alarm input channels. It is to receive relay

signal from the external alarm source. You can go to
dome menu to activate specified preset or patter.

f) When the activation mode is NO (normal open), dome

alarms when there is low voltage. High voltage will not
activate the alarm.

g) When the activation mode is NC (normal close), dome

alarms when there is high voltage. Low voltage will not
activate the alarm.

Note:
z

Dome alarm input message is ground mode.

z

Dome alarm input signal are two modes: normal open and

normal close.