Bp1 + hp1) filter patch – Intellijel Korgasmatron II User Manual

Page 37

Advertising
background image

CV

CUTOFF/BANDWIDTH

(BP1 + HP1) filter patch

35

signal to be

filtered

CUTOFF/BANDWIDTH

set with

A band-pass

always

<

B high-pass

CV

CUTOFF/BANDWIDTH

Monitoring (BP1 + HP1) filter at MIX in PARALLEL
configuration with 1:1 XFADE.

(BP1 + HP1) CUTOFF shift :
Manually set A & B cutoff, with

A band-pass cutoff always

<

B high-pass cutoff

. Keep same relative knobs position

for cutoff shift.

OR/AND

Input same CV signal in A & B FM 1 with same attenuation
levels.

OR/AND

Use FM 2 normalled input and set FM 2 B as FM 2 A.

(BP1 + HP1) BANDWIDTH set :
Manually set A & B cutoff, with

A band-pass cutoff always

<

B high-pass cutoff

. Keep different relative knobs

positions for bandwidth set.

OR/AND

Input different CV signals in A & B FM 1 with different
attenuation level.

OR/AND

Use FM 2 normalled input and set FM 2 B as inverted of
FM 2 A.

See (BP1 + HP1) filter chart for details on MIX out filter
curves.

A

B

out

freq.

(BP1 + HP1) out

Advertising