Special chime, Cross-zoning, System tests – Interlogix Simon XTi Quick Start User Manual

Page 6: Sensor test

Advertising
background image

To enable or disable the chime feature:

1. Open the Status & Settings screen. The gold icon indicates

an option is selected.

2. To change the value, press On or Off next to Chime

(depending on the settings your installer programmed, it
may not be possible to turn on the feature).

3. Press Close to exit.

Special chime

The special chime feature allows you to install motion sensors
in a patio or at the front door, and be notified when someone is
approaching those areas. These motion sensors are not used
for intrusion protection. The panel will chime, if the special
chime mode is enabled.

Note:

If there are no special chime sensors in your system, the

special chime option will not appear in the Status & Settings
screen.

To enable or disable the special chime feature:

1. Open the Status & Settings screen. Scroll down until you

find the Special Chime feature. The gold icon indicates an
option is selected.

2. To change the value, press On or Off next to Special Chime.

3. Press Status to exit.

Cross-zoning

Cross zoning (two-trip) refers to two different motion sensors
that must be tripped within two minutes of each other to report
an alarm to the central station. The Cross-zoning figure shows
the path of a person walking from the kitchen to the living room.
When the person is detected walking through the kitchen, the
motion sensor in the kitchen is tripped, sounding a local alarm.
If motion is detected by the living room motion sensor within
two minutes, an alarm report will be sent to the central station.

Figure 1: Cross-zone diagram

Motion sensor

Motion sensor

Path of person walking

System tests

Sensor test

You should test sensors one at a time to make sure they are
sending strong signals to the panel. You should test the sensors
at least once a week.

To perform the sensor test:

1. Enter the Status & Settings menu.

2. Scroll until System Tests is listed, Press Enter.

3. Enter your master code and press OK.

4. Press Sensor Test. All sensors learned into your system

will be listed

5. Test any sensor you want by tripping the sensor (see Table 6

below for details on how to trip each device).

6. The display will update with the total number of packets

received from each individual sensor (see Table 6 below for
minimum number of packets required).

Table 6: Tripping sensors for sensor test
Sensor Instructions

Minimum

packets required

Hardwire contact Open the hardwire contact.

1

Door/window

Open the secured door or

window.

6 of 8

Carbon

monoxide alarm

a

Press and hold the Test/Hush

button (approximately 5 seconds)

until the unit beeps two times,

and then release the button.

6 of 8

Glassbreak

a

Test with an appropriate glass

break sensor tester.

6 of 8

Motion sensor

Avoid the motion sensor field of

view for 5 minutes, and then

enter its view.

6 of 8

Smoke

Press and hold the test button

until the system sounds

transmission beeps.

6 of 8

Key fob

Press and hold the Lock and

Unlock buttons simultaneously

for 3 seconds.

6 of 8

Simon XT talking

touch screen

a

For sensor testing a 1.0. touch

screen, press and hold the

Emergency icon for 5 seconds.

For sensor testing a 1.1 or

greater touch screen, press the

Settings (gear) icon, scroll down,

and then press the RF Test icon.

6 of 8

a. Not investigated for use by UL.

Note:

Refer to specific sensor installation instructions for

complete operation and testing details.