NX-8V2 Control Panel Installation Instructions

Introduction

This is the NX-8V2-Control Panel Installation Instructions.

Installations should only be done by trained professionals. Use

this document to install the system with default settings that

comply with UL requirements.

To install the keypad, other peripherals, and sensors, refer to

the documentation for those devices.

P/N 466-2339 • REV B • 02MAR11

Installation

There are four slots for board insertions inside the metal

enclosure, two on the top and two on the bottom. These allow

the PC board to be positioned vertically (Figure 1 below).

When you slide the board between the grooves of the slots,

make sure the terminal strip is toward the front opening

(toward you) to allow for the wire connections.

Note: Install the metal enclosure with the door opening from

the top to bottom.

Figure 1: Board installation

NetworX keypad maximum wire run

Table 1 below lists wire lengths for one keypad at the end of

the wire. When connecting more than one keypad to the end of

the wire, a higher gauge wire is required

Table 1: Maximum keypad wire run

Length in feet

Wire gauge for NX-
8V2

Wire gauge for NX320-
E

250 24

22

500 20

18

1000 18

16

1500 16

14

2500 14

12

Terminal descriptions

Table 2 below describes the panel terminals.

Table 2: NX-8V2 terminals

Terminal Description

R1

House telephone ring (grey)..

R Telephone

ring

(red).

T

Telephone tip (green).

T1

House telephone tip (brown).

AC

AC input. Connect to a 16.5 V 40 or 50 VA Class ll UL
approved transformer.

EARTH

Earth ground. Connect to a cold water pipe or a 6 to 10 ft.
driven rod.

Bell + and
Bell -

If used as a siren output (default), the speaker rating
should be 15 watt at 8 or 16 ohm, or 30/40 watt at 4, 8, or
16 ohms. If voltage ouput is selected in location 37, this
output becomes voltage output, 12 VDC, 1 Amp maximum
load. Note: A 3.3 kohm resistor may be required across
the bell terminals when a 12 VDC siren is used. If no
resistor is used, you may experience voltage leakage into
the siren, which will cause these devices to output a small
signal.

KP Data

Connect to the data terminal on the keypads and the
expanders. Maximum number of devices (keypads plus
expanders) is 32. See Maximum Wire Run table.

KP COM

Connect to the common terminal on the keypads and the
expanders.