Zone type

Description

Zone type

Description

2. 24-hour
audible.

This zone creates an instant yelping siren alarm
regardless of the armed state of the control panel.

3. Entry/exit
delay 1

A trip starts entry delay 1. The lack of a trip during exit
delay enables the automatic bypass or instant mode if
programmed.

4. Follower with
autobypass
disabled

This zone is instant when the system is armed and no
entry or exit delays are being timed. It is delayed
during entry and exit 1 times. This zone does not
automatically bypass even if enabled in segment 1 of
Location 23.

5. Interior
follower with
autobypass

This zone is instant when the system is armed and no
entry or exit delay is being timed. It is delayed during
entry and exit 1 times. This zone automatically
bypasses if enabled in segment 1 of Location 23.

6. Instant

This zone creates an instant alarm whenever it is
tripped and the armed LED is on.

7. 24-hour
silent

This zone creates an instant silent alarm regardless
of the armed state of the control panel. It does not
display on the keypad.

8. Fire

This zone illuminates the fire LED and sounds the
temporal siren each time the zone is shorted. The fire
LED flashes rapidly indicating a problem if the zone is
open.

9. Entry/exit
delay 2

A trip starts entry delay 2. The lack of a trip during exit
delay enables the automatic bypass or instant mode if
programmed.

10. 24-hours
silent
supervised

This zone creates an instant silent alarm regardless
of the armed state of the control panel. It displays on
the keypad.

11. Reserved

12. Interior
follower with
cross zone

This zone is instant when the system is armed and no
entry or exit delay is being timed. It is delayed during
entry and exit delay times. If a

cross zone

is not being

timed, it starts a

cross zone

timer. If a

cross zone

is being

timed, it creates an instant alarm. This zone
automatically bypasses when enabled in segment 1.

13. Instant
entry guard

This zone creates on instant alarm whenever it is
tripped and the stay LED is off. It starts an entry delay
type 2 if it is tripped, the system is armed, and the
stay LED is on.

14. Entry/exit
delay 1 with
group bypass

A trip starts entry delay 1. This zone bypasses when
the group bypass command is entered at the keypad.
The lack of a trip during exit delay enables the
automatic bypass or instant mode if programmed.

15. Interior
follower with
group bypass

This zone is instant when the system is armed and no
entry or exit delays are being timed. It is delayed
during entry/exit delay times. This zone bypasses
when the group bypass command is entered at the
keypad. This zone automatically bypasses if enabled
in segment 1.

16. Instant with
group bypass

This zone creates an instant alarm whenever it is
tripped and the armed LED is on. This zone bypasses
when the group bypass command is entered at the
keypad.

17. Entry/exit
delay 1 with
tamper

A trip starts entry delay 1. The lack of a trip during exit
delay enables the automatic bypass or instant mode if
programmed. This zone type is used to enable the
tamper on a wireless transmitter.

18. Interior
follower with
tamper and
autobypass

This zone is instant when the system is armed and no
entry or exit delay is being timed. It is delayed during
entry and exit delay times. This zone automatically
bypasses if enabled in segment 1. This zone type is
used to enable the tamper on a wireless transmitter.

19. Instant with
tamper

This zone creates an instant alarm whenever it is
tripped and the armed LED is on. This zone type is
used to enable the tamper on a wireless transmitter.

20. Entry/exit
delay 2 with
tamper

A trip starts entry delay 2. The lack of a trip during exit
delay enables the automatic bypass or instant mode if
programmed. This zone type is used to enable the
tamper on a wireless transmitter.

21. Gas
detection

This zone creates an instant alarm regardless of the
armed state of the control panel. It displays on the
keypad and activates the keypad sounder

22. Low
temperature
detection

This zone creates an instant silent alarm regardless
of the armed state of the control panel. It displays on
the keypad and activates the keypad sounder.

23. High
temperature
detection

This zone creates an instant silent alarm regardless
of the armed state of the control panel. It displays on
the keypad and activates the keypad sounder.

24. Manual fire

This zone illuminates the fire LED and sounds the
temporal siren each time the zone is shorted. It also
flashes (rapidly) the fire LED, indicating a problem if
the zone is open.

25. Chime only

This zone creates no alarm regardless of the armed
state of the control panel. It chimes anytime it is
faulted and displays on the keypad. Local only.

26. Interior
follower delay 2

This zone is instant when the system is armed and no
entry or exit delay is being timed. It is delayed during
entry and exit 2 times. This zone automatically
bypasses if enabled in segment 1 of Location 23.

27. Interior
follower force
armable

This zone is instant when the system is armed and no
entry or exit delay is being timed. It is delayed 1 time
during entry and exit. This zone automatically
bypasses if enabled in segment 1.

28. Entry/exit
force armable
delay 2

A trip starts entry delay 2. The lack of a trip during exit
delay enables the automatic bypass or instant mode if
programmed.

29. Interior
follower with
activity
supervision

This zone is instant when the system is armed and no
entry or exit delay is being timed. It is delayed during
entry and exit delay times. It sends a report if the
zone activity time is reached without a change of
state. This zone automatically bypasses if enabled in
segment 1:

30. Entry/exit
with activity
supervision

A trip starts entry delay 1. It sends a report if the zone
activity time is reached without a change of state. The
lack of a trip during exit delay enables the automatic
bypass or instant mode if programmed.