NX-6V2 Control Panel Installation Instructions

Introduction

This is the NX-6V2-Control Panel Installation Instructions.

Installations should only be done by trained professionals. Use

this document to install the system with default settings that

comply with UL requirements.

To install the keypad, other peripherals, and sensors, refer to

the documentation for those devices.

Installation

There are four slots for board insertions inside the metal

enclosure, two on the top and two on the bottom. These allow

the PC board to be positioned vertically (

Figure 1

). When you

slide the board between the grooves of the slots, make sure

the terminal strip is toward the front opening (toward you) to

allow for the wire connections.

Note: Install the metal enclosure with the door opening from

the top to bottom.

Figure 1 Board Installation

NetworX keypad maximum wire run

Table 1

lists wire lengths for one keypad at the end of the wire.

When connecting more than one keypad to the end of the wire,

a higher gauge wire is required

Table 1: Maximum keypad wire run

Length in feet

Wire gauge for NX-6v2

Wire gauge for NX320-E

250 24

22

500 20

18

1000 18

16

1500 16

14

2000 14

12

Terminal descriptions

Table 2

describes the panel terminals

Table 2: NX-6V2 Terminals

Terminal Description

R1

House telephone ring (grey).

R Telephone

ring

(red).

T

Telephone tip (green).

T1

House telephone tip (brown).

EARTH

Earth ground. Connect to a cold water pipe or a 6 to
10 ft. driven rod.

AC

AC input. Connect to a 16.5 V, 40 or 50 VA Class II
UL approved transformer.

Bell + and

Bell -

If used as a siren output (default), the speaker rating
should be 15 watt at 8 or 16 ohm, or 30/40 watt at 4,
8, or 16 ohms. If voltage ouput is selected in location
37, this output becomes voltage output, 12 VDC, 1
Amp maximum load. Note: A 3.3 kohm resistor may
be required across the bell terminals when a 12 VDC
siren is used. If no resistor is used, you may
experience voltage leakage into the siren, which will
cause these devices to output a small signal.

KP DATA

Connect to the data terminal on the keypads and the
expanders. Maximum number of devices is 16
keypads plus 3 other de vices. See Maximum Wire
Run table.

KP COM

Connect to the common terminal on the keypads and
the expanders.

KP POS

Connect to the POS terminal on the keypads and the
expanders. Individually, this terminal is limited to 1
amp. Combined, this terminal and AUX PWR+ are
limited to 2 amps total current.

COM

Common negative wire of powered devices such as
motion detectors and smoke detectors.

AUXPWR +

Connect positive wire of all powered devices except
smoke detectors and keypads. Individually, this
terminal is limited to 1 amp. Combined, this terminal
and KP POS are limited to 2 amps total current.

P/N 466-2338 • REV B • January 2011