Location 3 - phone 1 dial attempts/backup control, Segment 1 - phone 1 dial attempts, Segment 2 - phone 1 backup control – Interlogix NX-6V2 REV B Installation Manual User Manual

Page 4: Location 4 - phone 1 events reported, Segment 1

Advertising
background image

a 0, the built-in communicator is disabled and the NX-6V2

functions as a local-only control.

Table 4 communicator formats

Data Format

Description

0

Local

Communicator is disabled

1

Universal 4+2

Two-digit event code 1800 Hz transmit
2300 Hz handshake double round parity
40 pps [1]

2

3+1 fast (or 4+1)

One-digit event code 1900 Hz transmit
1400 Hz handshake double round parity
20 pps

3 Reserved

Reserved

4

Pager

Two-digit event code DTMF
transmission

5

3/1 or 4/1 slow

1800 Hz transmit 2300 Hz handshake
double round parity 20 pps hex
capability

6

3/1 or 4/1 slow

1800 Hz transmit 1400 Hz handshake
double round parity 20 pps hex
capability

7

3/1 or 4/1 fast

1800 Hz transmit 2300 Hz handshake
double round parity 40 pps hex
capability

8

3/1 or 4/1 fast

1800 Hz transmit 1400 Hz handshake
double round parity 40 pps hex
capability

9

3/1 or 4/1 fast with
parity

1800 Hz transmit 2300 Hz handshake
single round parity 40 pps hex capability

10

3/1 or 4/1 fast with
parity

1800 Hz transmit 1400 Hz handshake
single round parity 40 pps hex capability

11

4+2 express

Two-digit event code DTMF
transmission

12

4+2 fast

Two-digit event code 1900 Hz transmit
1400 Hz handshake double round parity
20 pps

13

Ademco contact ID

DTMF

14

SIA

Frequency shift keys

15 Custom

format

See

Loc

16

3/1 or 4/1 slow

Same as 5, but sends the alarm event
code rather than the zone number

17

3/1 or 4/1 slow

Same as 6, but sends the alarm event
code rather than the zone number

18

3/1 or 4/1 fast

Same as 7, but sends the alarm event
code rather than the zone number

19

3/1 or 4/1 fast

Same as 8, but sends the alarm event
code rather than the zone number

20

3/1 or 4/1 fast with
parity

Same as 9, but sends the alarm event
code rather than the zone number

21

3/1 or 4/1 fast with
parity

Same as 10, but sends the alarm event
code rather than the zone number

22

SIA

SIA with area modifiers

[1] pulses per second

Location 3 - Phone 1 dial attempts/backup control

Location 3 has two segments of numerical data.

Segment 1 - Phone 1 dial attempts

Program the number of dial attempts (1 to 15) the

communicator makes to phone 1 before ending the notification

process. The default is 8, which means that the communicator

makes eight attempts to the first number.

Segment 2 - Phone 1 backup control

Program the backup control for phone 1. The default is 0.

Program a 0 in segment 2 to cause the NX-6V2 to make

the designated number of attempts to phone 2 before

setting the fail to communicate condition to stop reporting.

Program a 1 in segment 2 to cause the NX-6V2 to stop

trying to communicate after the designated number of

attempts have been made to phone 1.

Program a 2 in segment 2 to cause the NX-6V2 to make

the dial attempts in increments of two. The first two

attempts are made to phone 1, the next two attempts to

phone 2. This repeats until the total number of attempts

designated in segment 1 is completed.

Location 4 - Phone 1 events reported

Location 4 has two segments of feature selection data. Use

this location to select those events reported to phone 1.

If you do not want dual or split reporting, use Location 4 to

select all events to phone 1.

If you want dual or split reporting and the split is based on

the event type (alarm, open/close, etc.), use Location 4 to

select only those events that are reported to phone 1.

If you don’t want events reported to phone 1, program 0 in

Location 4 (disabling all options).

Segment 1

1. Alarms and alarm restores.

2. Opening and closings.

3. Zone bypass and bypass restores.

4. Zone trouble and trouble restores.

5. Power fail, low battery, power restore, and low battery

restore.

6. Bell cut, telephone line cut, bell cut restore, telephone line

restore.

7. Test reports.

8. Start and end programming, download complete.

4

NX-6V2 Control Panel Installation Instructions