Regulatory information

Contact information

FCC compliance

This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that
may cause undesired operation.

Complies with Part 68 FCC Rules.

ACTA (FCC) ID: GCQUSA-33408-AL-E

IC: 1175A-NXV2

2002/96/EC (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.recyclethis.info.

For contact information, see www.utcfireandsecurity.com or

www.interlogix.com.

For technical support, Toll-free: 888.437.3287 in the US

including Alaska, Hawaii, Puerto Rico, and Canada. Outside

the tool-free area: Contact your dealer.

Copyright © 2011 UTC Fire & Security. All rights reserved.

ANSI/SIA CP-01 requirements

CP-01 feature descriptions and specifications are listed in

Table 7

. The following are requirements for compliance with ANSI/SIA

CP-01 standards.

Note:

Where a conflict exists, UL requirements take precedence over ANSI/SIA requirements.

Minimum system requirements:

One control panel

Two keypads

Do not enable remote arming in SIA classified installations.

Off premise transmission must be in the SIA format.

Do not exceed 1 minute for the

abort window and entry delay.

Note:

A call-waiting cancel on a noncall-waiting line prevents successful connection to the central station

Table 7. CP-01 feature descriptions and specifications

CP-01 feature description

Feature description as
shown in manual

Progra
m
location

Seg/op
t

Default CP-01

required

setting

Exit 1 delay

24

2

60

45 to 240 seconds

Exit time

Exit 2 delay

24

4

60

45 to 240 seconds

Progress annunciation /
disable for silent exit <1>

Silent keypad option

93

2

All
annunciators
enabled

Allowed (individual keypads may be disabled)

Exit time restart (reexit)

This feature is not programmable in the panel.

Enabled

Auto stay arm on unvacated
premises

Auto bypass

23

1/3

Enabled

Enabled

Exit time and progress
annunciation/disable for
remote arm

This feature is not programmable in the panel. Exit time and
progress are always enabled.

Enabled (disabled for remote arming)

Exit 1 delay

24

1

30

30 to 240 seconds

Entry delays <2>

Exit 2 delay

24

3

30

30 to 240 seconds

Abort window - for
nonfire zones

Dialer delay

40

8

30

Enabled (may be disabled by zone/zone type,
but no cancel reports will be sent)

Abort window time - for
nonfire zones <2>

Dialer delay

40

8

30

15 to 45 seconds