3. Press

 to store the newly entered data. The keypad

advances to the next segment and displays its data.

Repeat this procedure until the last segment is reached.

4. To move to another location after exiting a location (Armed

LED illuminated):

Press the Police key for the next sequential location.

Press the Fire key for the previous location.

Press the Medical key for the same location.

5. To review the data in a specific location, repeat the above

procedure, pressing

 but with no numeric data entry.

Each time you press

, the programming data of the next

segment displays.

Exit a location

To exit the current programming location, do the following:

1. Press

the

 key. The Ready LED goes off and the Armed

LED goes on. You must press the

key to save the data.

2. To exit before the last segment, press # (Armed LED

illuminates).

You are now ready to enter another programming location. If

you attempt to program an invalid entry for a particular

segment, the keypad beeps three times indicating an error and

remains in that segment awaiting a valid entry.

Exit program mode

To exit program mode, do the following:

1. When you have completed all programming, press Exit to

leave the selected module.

2. If there is another module to be programmed, select it by

entering its address, followed by #. The procedure for

programming these devices is the same as for the control

panel, except the locations are for the module selected.

3. If no additional modules are to be programmed, press Exit

again to leave program mode.

Loading factory defaults

To load factory defaults, enter program mode, enter the device

address and number and then enter 9, 1, 0, #. The keypad

beeps three times indicating that loading is in progress. The

process takes about six seconds. You cannot exit the location

until loading is completed.

Enrolling modules and keypads

The NX-6V2 automatically finds and stores all keypads, zone

expanders, wireless receivers, and other modules connected

to the data terminal into the NX-6V2 memory. This allows the

modules to be supervised by the control panel.

To enroll the modules, do the following:

1. Enter program mode and program the desired settings for

each module.

2. When you exit program mode, the NX-6V2 automatically

enrolls the devices. The enrolling process takes about 12

seconds, during which time the Service LED illuminates. If

a speaker is attached to the NX-6V2, it clicks at this time.

If a siren or bell is attached to the NX-6V2, it sounds for

about one second. If the module is not detected, the

Service LED illuminates.

Note: User codes are not accepted during the enrolling

process.

Quick start programming locations

For most routine installations, the quick start locations allow

you to enable a majority of the options available with the NX-

6V2 (when communicating in Contact ID or SIA formats). The

quick start locations include:

Location 0 - Phone 1

Location 1 - Phone 1 account code

Location 2 - Phone 1 communicator format

Location 3 - Phone 1 dial attempts/backup control

Location 0 - Phone 1

Location 0 has 20 segments of numerical data. Use this

location to program phone 1. The default for each segment is

14.

To program a delay of four seconds, enter 13 in the

appropriate segment.

To program tone dialing, enter 15 in the segment where

tone dialing begins.

If the entire number is tone dialing, enter 15 in the first

segment.

Enter 11 for a *, and 12 for a #.

Location 2 - Phone 1 communicator format

Location 2 has one segment of numerical data. Use this

location to program the communicator format used to transmit

to the receiver connected to phone 1. Refer to your central

station receiver documentation to determine which format is

compatible.

Table 4

describes the formats for this location. If

you need a format other than those listed, review the override

options described in Loc to build the appropriate format.

Program a 15 to create a special format (in addition to the

entries in Location 18). The default is 0. If this location contains