Concord 4 Installation Guide

Content

Contact information 1

Description 1

Panel location 2

Power and wire length 2

Mounting the panel 3

Programming 4

Sensor group characteristics 7

Specifications 9

Regulatory information 9

Contact information

For contact information, see www.utcfireandsecurity.com
or www.interlogix.com.

For technical support, toll-free: 888.437.3287 in the US
including Alaska, Hawaii, Puerto Rico, and Canada.

Outside the tool-free area, contact your dealer.

© 2012 UTC Fire & Security Americas Corporation, Inc.

Interlogix is part of UTC Climate Controls & Security, a
unit of United Technologies Corporation. All rights
reserved.

Description

This is the Installation Guide for the following Concord 4
control panel models:

600-1021-95R Concord 4 RF

600-1022-95R Concord Express V4

600-1040 Concord Commercial V4

600-1042 Concord Hybrid

This manual provides information for installing a basic
UL Listed Fire and Security System. To modify or use for
other purposes, visit the UTC Fire & Security website for
additional instructions and training.

Table 1 below shows the standard panel capabilities.

Table 1: Panel capabilities

Capabilities

Concord Express v4

Concord 4/Concord
Com mercial v4

Zones

32

96

Partitions

2

6

Bus devices

16

16

User codes

16

230

Table 2 below describes the basic panel (out-of-box)
hardware capabilities for all panels:

Table 2: Panel hardware capabilities

Pow er

Input for an AC step-dow n, plug-in style
transformer.

Auxiliary pow er
output

Output that supplies 9 to 14 VDC w ith up to 1
amp for bus devices and hardw ired detectors,
such as smoke and motion detectors.

Bus A and B

Input and output that provides communication
betw een bus devices and the panel.

Siren driver

Output that can drive an 8-ohm load and provides
intrusion and fire alarm sounds for partition 1 (6
w atts maximum).

Tw o onboard
outputs

Can be used to activate other signaling devices
based on system events. Out 1 is a 9 to 14 VDC
source output, limited to 1.0 amp maximum. Out
2 is an open-collector output, rated up to 14 VDC,
300 mA maximum.

Microphone input

Input used for tw o-way audio w hen used in
conjunction w ith the Interrogator 200 audio
verification module.

Eight supervised
hardw ired zones

Inputs for various hardw ired detectors. Zone 8
can be set up in programming to accept tw o-wire
smoke detectors. It sources 9 to 14 VDC, 90 mA
maximum.

Built-in RF
receiver

Allow s use of up to 96 or 32 319.5 MHz crystal
and/or SAW learn mode w ireless sensors and
touchpads.