Concord 4 Installation Guide

3

Device

Max. w ire
length to
panel

Standby
m A draw

Alarm m A
draw

Interrogator AVM

22 ga.: 110 ft.
18 ga.: 260 ft.

45 mA

300 mA

Tw o-w ire smoke detectors
(429AT, 429C, 429CT,
521B, 521BXT, 521NCSXT

22 ga.: 330 ft.
18 ga.: 330 ft.

70 uA

60 mA

Tw o-w ire smoke detectors
(system sensor 2400,
2400TH)

22 ga.: 330 ft.
18ga.: 330 ft.

120 uA

80 mA

Hardw ired interior siren (13-
949)

22 ga.: 750 ft.
18 ga.: 1,500 ft.

0 mA

85 mA

Piezo dynamic exterior siren
(13-060)

22 ga.: 750 ft.
18 ga.: 1,500 ft.

0 mA

150 mA

Speaker siren (60-528 or
13-060)

18 ga.: 100 ft.

0 mA

500 mA

1

Maximum current draw for the SnapCards does not include the load

w hich may be applied to their auxiliary DC supply.

Note:

When installing SuperBus 2000 RF receiver

modules, the antenna tamper feature must be set to off.

Table 4 below describes the total system wire lengths
allowed for all SuperBus 2000 devices when installing
systems using unshielded or shielded cable. The
maximum wire length for individual devices is shown
instable below.

Table 4: Total system wire lengths

Wire type

Total system w ire

18-gauge, unshielded

4,000 ft.

18-gauge, shielded

3,000 ft.

22-gauge, unshielded

4,000 ft.

22-gauge, shielded

3,000 ft.

After determining panel location, run all necessary wires
to that location using the guidelines in Table.

Table 5: Device w ire requirements

Device

Wire requirements

AC pow er transformer 2-conductor, 18-gauge, 25 ft. max.

Earth ground

Single conductor, 16-gauge solid, 25 ft. max.

Telephone (RJ-31X)

4-conductor

Detection devices

2- or 4-conductor, 22-gauge, 1,000 ft. max.

2- or 4-conductor, 18-gauge, 2,500 ft. max.

(based on 30 ohms max. loop resistance
including device)

Speakers

2-conductor, 18-gauge, 100 ft. max.

Device

Wire requirements

SuperBus 2000
devices

4-conductor, 22- or 18-gauge

Interrogator 200 AVM
pow er and microphone

4-conductor, 22-gauge, shielded

Tw o-w ire smoke
detectors

2-conductor, 22-gauge, 330 ft. max.

2-conductor, 18-gauge, 830 ft. max.

Mounting the panel

Mount the panel to the wall or wall studs.

Caution:

Make sure you are free of static electricity

whenever you work on the panel with the cover open. To
discharge any static, first touch the metal panel chassis,
and then stay in contact with the chassis when touching
the circuit board. We recommend using a grounding
strap.

To mount the panel:

1. Remove the panel door and remove the necessary

wiring knockouts. Be careful not to damage the
circuit board.

2. Feed all wires through wiring knockouts and place

the panel in position against the wall.

3. Level the panel and mark the top and bottom

mounting holes.

4. Install anchors where studs are not present.

5. Partially insert screws into the two top mounting hole

locations, then hang the panel on the two screws.

6. Recheck for level, insert the two lower screws, and

tighten all four mounting screws.

Figure 1 below shows the main component locations.

Figure 1: Panel com ponents

EPROM

Antennas

Mounting hole

Mounting hole

Mounting holes

Snapcard
connector

Terminal strip

Programming
touchpad
header

Battery
terminals