Interlogix Concord 4 REV C Installation Manual User Manual

Page 10

Advertising
background image

10

Concord 4 Installation Guide

Table 11: SIA setting requirements

Function

Default setting

Required setting

Exit extension

On

On

Duress code

Disabled

Disabled

Dialer abort delay

30 seconds

15 to 45 seconds

Cancel message

On

On

Call w ait cancel

Disabled

On if reporting to
central station and
customer has call
w aiting service.

Entry delay

30 seconds

30 to 240 seconds

Exit delay

60 seconds

45 to 184 seconds

Sw inger limit

1

1

Smoke verify

Off

On if smoke alarms
are programmed into
system.

Cross zone

Disabled

Enabled for zones
w ith high probability of
false alarms

Table 12 below describes nonprogrammable (hard-
coded) system operation, as required to meet ANSI-SIA
CP-01 and is provided only for your reference.

Table 12: ANSI-SIA CP-01 requirements

Function

Operation

SIA false alarm

Enabled

Auto stay arming

Enabled

Disarm during entry delay

Enter code only (or 1 + CODE)

Cancel alarm

Enter code only (or 1 + CODE).

Abort annunciation

Enabled

Exit error

Enabled

Entry/exit progress annunciation

Enabled

Note:

You may use the silent arming feature to suppress

arming level and exit beeps for the current arming
period. Refer to the Concord 4 user manual for more
information on silent arming.

Commercial burglary alarm system unit (UL 1610)

Basic system using control panel 600-1040, SuperBus
2000 RF transceiver module (600-1025-01-95R), plus
the following:

Hardwired magnetic contact (13-068 or 13-071) or

wireless learn mode door/window sensor (60-499).

SAW PIR sensor (60-639-95R), crystal PIR sensor (60-

703-95R), or DS924i PIR sensor (60-511-01-95).

UL approved bell/housing, such as Ademco #AB12M or

equivalent.

Immediate beeps set to on.

UL 98 options set to on.

Receiver failure set to on (if wireless devices are used).

RF TX timeout set to 4 hours.

24-hour tamper set to on.

System tamper set to on.

Automatic phone test set to on.

Phone text frequency set to 1.

Next phone test set to 1.

Siren verify set to on.

AC failure set to on.

Exit delay set to 120 seconds or less.

Quick exit set to off.

Two-trip error set to off.

Alarm verify set to off.

Disable trouble beeps set to off.

Phone number must be programmed.

High level reports set to on.

Low level reports set to on.

Communication failure set to on.

Extended delay set to off.

Sleep time set to off.

Siren timeout set to 4 minutes or more.

UL 1610 24-hour backup

Same as UL 1023 and 985.

UL 1635 digital alarm communicator system

For UL 1635 installations, entry delay plus dialer abort
delay must not exceed 60 seconds. Same as UL 1023,
985, and 1610 plus:

AC failure set to on.

Phone number must be programmed.

Low CPU battery set to on.

Next phone test set to 1.

Phone test frequency set to 1.

High level reports set to on.

Low level reports set to on.

Communication failure set to on.

RF TX timeout set to 4 hours.

Central station reporting

The panel has been tested with the following central
station receivers using SIA and Contact ID reporting
formats:

CS-5000 central station receiver

Sur-Gard central station receiver with models SG-DRL2A

and SG-CPM2

Osborne Hoffman central station receiver