Interlogix Concord 4 REV C Installation Manual User Manual

Page 11

Advertising
background image

Concord 4 Installation Guide

11

Note:

The installer must verify the compatibility between

this panel and the central station receivers being used.

UL Canada listed installations

This section describes the requirements for CUL (UL
Canada) listed installations.

Residential burglary alarm system unit (ULC subject
C1023-1974)

Basic system as described for UL 1023 listed
installations plus:

Hardwired magnetic contact (13-068 or 13-071) or

wireless learn mode door/window sensor (60-362)

Siren timeout set to 5 minutes or more

Residential fire warning system control unit (ULC-
S545-M89)

Basic system as described for UL 985 listed installations
plus:

Hardwired smoke detector: System sensor models 2400

or 2400TH learned into sensor group 26, or ESL models

429AT, 429CT, 521B, 521BXT, 521NCSXT, 711U, 711UT,

721U, 721UT, TS7-2, or TS7-2T learned into sensor group

26.

Wireless smoke sensor 60-319.5 60-848-02-95, TX-6010-

01-1learned into sensor group 26.

Siren timeout set to 5 minutes or more.

RF TX timeout set to 4 hours (if system includes SuperBus

2000 RF transceiver and wireless smoke sensors).

Immediate trouble beeps set to on.

Note:

For 24-hour backup, external power drain is

limited to 90 mA (during normal standby condition) using

a 4.5 or 5.0 Ah battery, or 190 mA continuous using a
7.0 Ah battery.

California State Fire Marshall listed installations

Same as Household Fire Warning System (UL 985) plus:

Smoke verify must be set to off.

FCC compliance

Changes or modifications not expressly approved by
UTC Fire & Security can void the user’s authority to
operate the equipment.

This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful
interference when the equipment is operated in a
residential environment. This equipment generates,

uses, and can radiate radio frequency energy and, of not
installed and used in accordance with the instruction

manual, may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation.

If this equipment does cause harmful interference to
radio or television reception, which can be determined
by turning the equipment off and on, the user is

encouraged to try to correct the interference by one or
more of the following:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and

receiver.

Connect the affected equipment and the panel receiver to

separate outlets, on different branch circuits.

Consult the dealer or an experienced radio/TV technician

for help.

Part 68. This equipment complies with Part 68 of the
FCC rules. Located on this equipment is a label that
contains, among other information, the FCC registration
number and the ringer equivalence number (REN) for
this equipment. If requested, this information must be
provided to the telephone company.

FCC Part 68 registration number: US: B4ZAL02B55910.

Advertising