Module list, Control panel programming, Enter program mode – Interlogix NX-6V2 REV B Installation Manual User Manual

Page 2: Select the module to program, Program a location

Advertising
background image

ZONE 7

Connect to one side of zone 6 loop. Connect the
other side to com terminal. Open or short causes
alarm. Only zone 6 can be used for a two-wire
smoke detector, connected with a 680 ohm EOL
resistor. Refer to the wiring diagram. Program
location 37, segment 6, option 1. Only zone 6 can be
a two-wire zone.

COM

Common (-) terminal for zones 5 and 6.

ZONE 6

Connect to one side of zone 5 loop. Connect the
other side to COM terminal. Open or short causes
alarm.

ZONES 1 to 5 Connect as described for zones 5 and 6.

AUXOUT 4

(SMOKE +)

Smoke detector power 12 VDC (for those
jurisdictions which allow the Priority zone to be used
with smoke detectors). Current limited to 250 mA
when output is positive and 250 uA when output is
negative. This output defaults to Smoke Power, but
can be reconfigured. Zone 7 may be used for a 2-
wire smoke detector using a 680 ohm EOL resistor.

AUXOUT 1 to
3

Connect negative lead of low current device [relay,
LED (install 1kohm resistor in series with LED), etc.]
Connect positive lead of device to COM. Current is
limited to 50 mA when output is negative, and 250
uA when output is positive

.

Module list

Table 3

shows the modules that are compatible with the NX-

6V2 system. Additional information and a catalog listing all

system components is available from UTC Fire & Security

Customer Support.

Table 3 Modules that can be added to the NX-6V2

Part Description

NX-108E

8-zone LED keypad

NX-116E

16-zone LED keypad

NX-124E

24-zone LED keypad

NX-148E

Alphanumeric 48-zone LCD keypad

NX-148E-RF

Alphanumeric 48-zone LCD keypad with built-in 48-
zone wireless receiver

NX-200

Zone doubling kit (includes one hundred 3.74k and
one hundred 6.98k resistors)

NX-320E

Smart power supply and bus extender

NX-408E

8-zone wireless expansion module

(UL listed part #60-904)

NX-416E

16-zone wireless expansion module

(UL listed part #60-904)

NX-448E

48-zone wireless expansion module

(UL listed part #60-904)

NX-508E Eight-output

module

NX-534E

Two-way listen-in module

NX-540E

Operator telephone interface module

NX-548E 48-zone

wireless

receiver

NX-591E-
GSM

Cell interface

NX-1192E

192-zone LCD keypad

NX-1208E

8-zone LED keypad

NX-1248E

48-zone LCD keypad

NX-1308E

8-zone LED door design keypad

NX-1316E

16-zone LED door design keypad

NX-1324E

24-zone LED door design keypad

NX-1448E

48-zone fixed language icon keypad

[1] These products have not been tested and approved by
Underwriters Laboratories, In.

[2] These wireless devices are UL listed only for residential
applications.

Note:
The NX-6V2 control panel sends a trouble condition once each
hour if it senses that no devices have been enrolled. This report
shows expander trouble--device zero (0).

Control panel programming

Programming the control panel requires you to enter program

mode, select the module to program, program a location, and

then exit the location and program mode.

Enter program mode

To enter program mode, do the following:

1. Press

8. The five function LEDs (Stay, Chime, Exit,

Bypass, and Cancel) begin flashing.

2. Enter the go to program

code (default is 9, 7, 1, 3). If the

go to program code entry is valid, the Service LED flashes,
and the five function LEDs illuminate. You are now in

program mode and can select the module to program.

Select the module to program

Since all modules connected to the NX-6V2 are programmed

through the keypad, the module you are programming should

be the first entry. To select the module to program, enter 0, #.

The 0 is the module number of the control, and # is the entry

key. You can find other module entry numbers in the module

documentation.

Program a location

Once you enter the module number, the Armed LED

illuminates, indicating the keypad is waiting for you to enter a

programming location. To program a location, do the following:

1. To access any location, enter the desired programming

location, followed by #. If the location is a valid location,

the Armed LED extinguishes, the Ready LED illuminates,

and the binary data for the first segment of the location is

shown by the Zone LEDs.

2. While entering new data, the Ready LED begins flashing

to indicate a data change in process.

2

NX-6V2 Control Panel Installation Instructions