protected area, is acceptable, provided it is rated for outside

service and alarm conditions are transmitted to:

a) The dispatch location of the law enforcement agency having

jurisdiction over the protected property or

b) A central station or residential monitoring station complying

with the Standard for Central-Station Alarm Services, UL 827.

In a mercantile burglar alarm system, an alarm sounding

device located within the area of greatest protection, or outside

the area of greatest protection but within an area protected by

an alarm system and that shares a common control unit with

the system installed in the area of greatest protection, is

acceptable provided it is rated for inside service and alarm

conditions are transmitted to:

a) The dispatch location of the law enforcement agency having

jurisdiction over the protected property or

b) A central station or residential monitoring station complying

with the Standard for Central-Station Alarm Services, UL 827.

An inside sounding device shall be mounted at least 10 feet

(3.05 m) above the floor or at the surface of the ceiling. When

there is fixed construction within the area that could provide

access for an intruder, the alarm sounding device shall also be

mounted at least 4 feet (1.2 m), as measured horizontally away

from the edges of the fixed construction or at least 10 feet

(3.05 m) above it so as to minimize access by an intruder.

Table 6: Use markings

Model number

Use marking

Subassemblies

NX-8 (*S)

Res Fire1 and Burg2, Com Burg4, Acc5,
Homehealth Care Control Unit
Motherboard

NX-8E (*S)

Res Fire1 and Burg2, Com Burg4, Acc5,
Homehealth Care Control Unit
Motherboard

NX-8V2 (*S)

Res Fire1 and Burg2, Com Burg4, Acc5,
Homehealth Care Control Unit
Motherboard

NX-508, NX-508E

Res Fire1 and Burg2, Com Burg4, Acc5
Output

NX-507

Res Fire1 and Burg2, Com Burg4, Acc5
Relay Output Module

NX-216, NX-216E

Res Fire1 and Burg2, Com Burg4, Acc5
Zone Expander

Accessories

Model number

Use marking

NX-148, NX-148E (*S),
NX-124, NX-124E (*S),
NX-116, NX-108, NX-
108E (*S), NX-1208E
(*S), NX-1248E (*S), NX-
1308, NX-1308E, NX-
1316, NX-1316E, NX-
1324, NX-1324E (*S),
NX1348E (*S), NX-
1508E, NX-1516E (*S),
NX1616E, NX-1648E

Res Fire1 and Burg2, Com Burg4, Acc5 ,
and Homehealth Care Keypad

NX-148E-RF (*S)

Res Fire1 and Burg2, Acc5 , and
Homehealth Care Keypad

NX-003

Res Fire1 and Burg2, Acc5 Enclosure

1 Res Fire = Residential Fire
2 Res Burg = Residential Burglar
3 Com Fire = Commercial Fire
4 Com Burg = Commercial Burglar
5 Acc = Access Control

Table 7: System markings (+)

Model number Signaling

means

Other

NX-8 (*S), NX-
8V2 (*S)

DACT

Central Station, Local Mercantile
and Police Station Connected

NX-8E (*S)

DACT

Central Station, Local Mercantile
and Police Station Connected,
Proprietary

WARNING:

Electrical codes will vary, depending upon the

country and city where the system is installed. It is the

installer’s responsibility to ensure that the electrical installation

is safe and conforms to all applicable codes, laws, or

regulations. Only qualified persons should connect this device

to the main supply..

Minimum system configurations for UL installations

The following requirements apply to residential fire, residential

burglary, and commercial burglary installations.

The NetworX NX-8V2 panel is necessary to initiate

residential and commercial installations.

At least one compatible keypad is needed for all

applications.

The AD10-12 bell and UL Approved bell-housing shall be

used for all applications.

Commercial UL applications require the NX-003-C metal

enclosure. Supplied screws to be used.

A minimum of two keypads is required for home health

applications, and each keypad must be set to a unique

address.

The wireless devices are only UL listed for residential

applications.

8