NX-8V2 Control Panel Installation Instructions

9

The DACT shall be enabled for all commercial burglary

applications.

UL requires that an alarm panel work for a minimum amount of

time during a power failure.

Table 8

below

lists the battery

capacities needed to meet time limits based on the current

draw of the panel and all attached devices.

Table 8: Battery capacities

Standby time Total

auxiliary
current

Standby battery
capacity

Alarm current

24-hours 1.9

A

1.25 A
600 mA

51 Ah
34 Ah
17 Ah

600 mA
1 A
1 A

48-hours 900

mA

600 mA
300 mA

51 Ah
34 Ah
17 Ah

1 A
1 A
1 A

72-hours 600

mA

400 mA
200 mA

51 Ah
34 Ah
17 Ah

1 A
1 A
1A

Note: Calculations are based on three 17 A batteries.

WARNING:

Replace only with a Panasonic LC12V4BP or

Yuasa NP$-12 battery. There is a risk of explosion if the

battery is replaced with an incorrect type.

If separate power supplies are necessary to accommodate

additional devices, safety standards require that each power

supply be prominently marked with adequate instructions for

removing all power from the unit.

Caution:

Observe polarity when installing a new battery.

Installing the battery backwards may cause damage to the

panel. Dispose of used batteries in according to the

manufacturers instructions and/or local government authorities.

Specifications

Operating power

16.5 VAC 40 or 50 VA transformer

Auxiliary power
w/25 VA
transformer
w/40 or 50 VA
transformer

(MG Electronics part
number 22-156 for US
or 22-156-CN for
Canadian installations)


12 VDC regulated 500 mA
12 VDC regulated 1 A

Loop resistance
Standard loop


300 ohms maximum

Fuse

Type T 200 mA 250 VAC

Built in siren driver

Two tone (temporal and yelp)

Loop response

Selectable 50 mS or 500 mS

Operating temperature

32 to 120°F (0 to 49°C)

LED keypad

Current draw
Zones normal w/o
sounder
Dimensions

130 mA max.
55 mA

6.4 x 4.0 x 1.1 in. (16.3 x 10.2 x 2.8 cm)

NX148E LCD keypad

Current draw
Without sounder
Dimensions

110 mA max.
75 mA
6.4 x 5.3 x 1.0 in. (16.3 x 13.5 x 2.5 cm)

Metal enclosure
dimension

11.25 x 11.25 x 3.50 in. (28.58 x 28.58 x 8.90
cm)

Shipping weight

9 lb. (4.1 kg)

Regulatory information

Manufacturer

UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943,
USA

FCC compliance

This device complies with part 15 of the FCC
rules. Operation is subject to the following
conditions:

This device may not cause harmful interference.

This device must accept any interference
received, including interference that may cause
undesired operation.

Changes or modifications not expressly approved
by the party responsible for compliance could
void the user’s authority to operate the
equipment.

Complies with Part 68 FCC Rules.

ACTA (FCC) ID: GCQUSA-33408-AL-E

IC: 1175A-NXV2

Contact information

www.utcfireandsecurity.com

or

www.interlogix.com

For customer support, see

www.interlogix.com/customer-

support

Copyright © 2011 UTC Fire & Security. All rights reserved.