Interlogix NX-148E-RF User Manual

Page 3

Advertising
background image

NX-148E- RF LCD Touchpad w ith Receiver Installation Instructions

3

RM: receiver module

HE: hardwire expander

P: panel

This gives you all the programming information in one place

and facilitates the programming process.

Zone locations 401 to 592

Zone locations 401 to 592 are not numbered in

Table 11

since

these locations vary depending on location 594, Receiver Zone

Bank Setting.

For example, if location 594 is set to 3, the first available

location is 425. The total number of available locations is

dependant on the zone limits for both the panel and receiver.

The default settings shown for Segments 1 and 2 in the first

zone location apply to all zone locations.

Set touchpad number and partition (94)

To set the touchpad number and partition, do the following:

1. Enter * 94.

2. Enter your program code.

3. Enter the touchpad number (see

Table 2

) and press *.

4. Enter the partition number and press *.

5. To exit, press #.

Table 2. Device num bers

Partition

Touchpa
d

1

2

3

4

5

6

7

8

1

192

193

194

195

196

197

198

199

2

200

201

202

203

204

205

206

207

3

208

209

210

211

212

212

214

215

4

216

217

218

219

220

221

222

223

5

224

225

226

227

228

229

230

231

6

232

233

234

235

236

237

238

239

7

240

241

242

243

244

245

246

247

8

248

249

250

251

252

253

254

255

Add transmitters

To add transmitters to the touchpad receiver, do the following:

1. Enter * 8 at the touchpad.

2. Enter your program code (factory default is 9 7 1 3).

3.

Enter the devic e numbe r (

Table 2

) and pres s #.

4.

To load factory default s and clear unwant ed informat ion in

memory for new installat ions , enter 9 1 0 #.

5. To determine the starting zone number for the specific

touchpad receiver on new installations, set the receiver

zone bank (Location 594) The bank setting is based on

the zone capabilities of both the receiver and the panel

and must be set before you add (learn) transmitters.

6.

Enter 400 # to enter the sens or (trans m itt er) learnin g

location.

7. Enter a zone number (1 to 192) and press *. Three beeps

from the touchpad indicates an entry error. This occurs if

you enter a transmitter number that is not within the
receiver’s zone block or if you try to learn a transmitter that
is already learned into the receiver.

Note: If you change your mind about your entry, enter

400

# 0*

to terminate programming and start over from step 6.

8.

Trip the desired trans mitt er (within 250 second s) as

desc rib ed in

Table 3

. Listen for the ding dong for

confirm at ion

Table 3. Tripping transmitters

Transmitter

Action

Door/w indow , shock, glass
guard, freeze, UFT

Activate tamper sw itch by removing
cover.

Door/w indow with external
contact

Activate tamper sw itch by removing
cover.

Feature 4

—Input option 1, must be on.

Recessed door/w indow

Activate tamper sw itch by removing
circuit board until tamper sw itch is
exposed.

Micro door/w indow and

Micro recessed door/w indow

Refer to the installation instructions for
the specific sensor for activation
information.

SlimLine door/w indow

Remove cover, then press the button
on the top of the sensor, or activate
the tamper sw itch by removing the
cover.

PIR

Refer to the installation instructions for
the specific sensor for activation
information.

Smoke detector w ithout
tamper sw itch

Press and hold the test button.

Smoke detector w ith tamper
sw itch

Trip the tamper sw itch. Feature 4

Input option 1, must be on.

Heat detector

Press, then release the tamper sw itch.

Single button panic

Press and hold the button.

Dual button panic

Press and hold both buttons together.

Keyfobs

Press and hold the arm and disarm
buttons together.

Repeater

Press, then release the tamper sw itch.

Advertising