NX-148E- RF LCD Touchpad w ith Receiver Installation Instructions

9

Silent exit (EXIT)

To silence the exit beeps during exit delay (while the system is

disarmed), do the following:

1. Enter * EXIT.

2. Enter your user code.

3. To exit, press #.

Reference tables

Table 9. Service menu messages

Message

Explanation

Control over current

A short circuit of a pow er supply has
occurred.

Control siren trouble

Open circuit on the bell or siren circuit.

Control box tamper

(Optional) The box tamper circuit has
activated.

Control phone trouble

The phone line connected to the control is
not operating properly.

Control fail to comm.

The control made an unsuccessful attempt
to communicate a message to the central
station.

Control ground fault

A short to ground has been detected on a
control circuit.

Control loss of time

Your system has lost total pow er and needs
the clock reset.

Control pow er trouble

The main pow er to the system is off.

Control low battery

The standby battery is low .

Expansion aux comm
fail

A auxiliary reporting device (i.e. NX-580E,
NX-582E, etc.) has failed to communicate.

Expansion over
current

A short circuit of an expansion devices
pow er supply has occurred.

Expansion pow er
trouble

The main pow er to an expansion pow er
supply is off.

Expansion low battery An expansion pow er supply has a low

battery.

Expansion box tamper A box containing an expansion device has

been opened.

Expansion RF jammed A radio receiver is being jammed.

Expansion trouble

An expansion device or touchpad is not
reporting to the control panel.

Expansion siren
trouble

An expansion device has detected trouble
on the bell or siren circuit.

Zone tamper, press *

A zone is tampered. Press * to identify the
tampered zone.

Zone low battery,
press *

A w ireless device has a low battery. Press *
to identify the zone.

Zone lost, press *

A w ireless or multiplexed zone device is not
reporting to the control. Press * to identify
the zone.

Zone trouble, press *

A zone is experiencing trouble. Press * to
identify the zone.

Table 10. Log m essages

Display

Description

TXlobat

Transmitter low battery

ZN Lost

Zone lost - A w ireless multiplexed zone
device is not reporting to the control.

Duress

The control has been armed or disarmed
w ith a Duress code.

Man Fire

Manual fire - Touchpad

Fire

has been

activated.

Aux 2

Auxiliary 2 - Touchpad

Medical

has been

activated.

Panic

Touchpad

Panic

has been activated.

KP Tamper

Touchpad Tamper - The touchpad tamper
has been activated.

BoxTamp

Box Tamper - The box tamper circuit has
been activated.

AC Fail

AC failure has been detected.

OverCur

Over current - A short circuit of a pow er
supply has occurred.

Srn Tamp

Siren tamper - A siren or speaker tamper
has been detected.

Tel Flt

Telephone fault - A telephone fault or
tamper has been detected.

Exp Trb

Expansion trouble - An expansion device or
touchpad is not reporting to the control.

Log Full

The event log is full.

Open

Reports, user number, date, time and
partition of opening.

Close

Reports, user number, date, time and
partition of closing.

Exit Err

Exit error - Entry/exit zone w as faulted w hen
the exit delay expired.

Rec Close

Recent close - An alarm occurred w ithin 5
minutes of the control being armed.

Autotest

Automatic test - Sending a communicator
test at a specified interval.

Start Prog

Start programming - Local Programming
has started.

End Prog

End programming -Local programming has
ended.

Start Dnld

Start dow nload - Dow nload session has
started.

End Dnld

End dow nload - Dow nload session has
ended.

Cancel

Cancel w as initiated w ithin 5 minutes of an
alarm.

Gnd Flt

Ground fault - A short to ground has been
detected.