NX-148E-RF LCD Touchpad w ith Receiver Installation Instructions

9. To program remaining transmitters, repeat steps 6 to 8.

10. To exit program mode, press EXIT EXIT.

Transmitter options

Door/window transmitter settings

To set features 4 (Input option 1) and 5 (Input option 2) for

door/window transmitters, do the following:

To disable the transmitter’s internal reed s witches, turn on
feature 4.

Turn on feature 5 for a normally closed (N/C) external

contact; turn off feature 5 for a normally open (N/O)

external contact.

Wireless smoke detector settings

To set feature 4 (Input option 1) for wireless smoke detectors,

do the following:

For wireless smoke detectors with tamper switches, turn

feature 4 on to enable the tamper feature.

For wireless smoke detectors without tamper switches,

turn feature 4 off (disabled).

Note: Feature 4 must be off (disabled) when using

wireless smoke detectors without tamper switches.

4-button keyfob settings

Keyfob functions 1 and 2 can be used to control relays,

outputs, or X10 devices. See Locations 593 and 594 in Error!

Reference source not found..

To set features 4 (Input option 1) and 5 (Input option 2) for 4 -

button keyfobs, do the following:

To change the Light button to keyfob function 1, turn on

feature 4.

To change the Star button to keyfob function 2, turn on

feature 5.

Partition settings for keyfobs

To program partition settings, do the following:

1. Enter * 8 at the touchpad.

2. Enter your program code (factory default is 9 7 1 3).

3. Enter the device number and press # (see

Table 2

).

4. Enter the location number and press #. For example, enter

401 # to enter location 401, segment 1. Press * for

segment 2.

5. Press the touchpad button that corresponds to the keyfob

partition number you want to change. The number will be

displayed for the keyfob partitions. Press the partition

number to toggle the partition on and off.

6. To continue programming keyfob transmitter partition

settings, repeat steps 4 to 8.

7. To exit program mode, press EXIT EXIT.

Transmitter supervision windows

To change the transmitter supervision windows, do the

following:

1. Enter * 8 at the touchpad.

2. Enter your program code (factory default is 9 7 1 3).

3. Enter the device number and press # (see

Table 2

).

4. Enter 595 # to enter location 595, segment 1.

5. Enter the new normal supervision time (0 to 255) and

press *. If you enter 0, it will set the normal supervision

time to 256 hours

Caution:

Do not set the normal or fire supervision windows to

1 hour. This causes false trouble reports from all learned

wireless transmitters.

1. Enter the new fire supervision time (0 to 255) and press *.

If you enter 0, it will set the fire supervision window to 256

hours.

2. Enter the new short supervision time (up to 30 minutes).

The short supervision setting prevents arming if a

transmitter has not checked in within the set time. This

applies only to specific countries outside the U.S. Check

the control panel installation manual to determine if this

setting is available. Enter a number higher than 30 (the

default value is 40) to disable the feature.

3. Press * to save any changes. The panel is now waiting for

the next location entry.

Note: If you press

# it

does not save changes to the

current segment, but it does save changes made in

previous segments.

4. To exit program mode, press EXIT EXIT.

Delete transmitters

This procedure makes the receiver ignore a transmitter but
does not remove transmitter identification from the receiver’s
memory. The transmitter can be reactivated later or a new one

can be learned into the zone.

To delete a transmitter, do the following:

1. Enter * 8 at the touchpad.

2. Enter your program code (factory default is 9 7 1 3).

3.

Enter the devic e numb er and pres s # (see

Table 2

).

Advertising