Interlogix NX-148E-RF User Manual

Page 5

Advertising
background image

NX-148E- RF LCD Touchpad w ith Receiver Installation Instructions

5

4. Enter the zone location and press #. For example, enter

407 # to delete zone 7.

5. To change transmitter feature 1 (Transmitter enabled),

enter 1 and press *. The 1 turns off to indicate the feature

change.

6. To delete additional transmitters, repeat steps 3 to 5.

Note: To delete all transmitters and load factory defaults,

enter 910 #.

7. To exit program mode, press EXIT EXIT.

Transmitter testing and troubleshooting

Test all transmitters to verify correct programming and

operation. Location 600 gives the number of rounds of the last

transmitter learned in. A minimum of 7 to 8 transmissions is

required for all transmitters. If the number of transmissions is

less than the minimum required, supervisories can occur.

Rotate the mounting position (90, 180, or 270 degrees) of any

transmitter that consistently tests below margin and retest.

If rotating the transmitter mounting position does not improve

signal reception or is not practical, move the transmitter to

different locations near the preferred mounting area. Test each

location until the transmitter consistently tes ts good, then

mount the transmitter.

Touchpad programming

To program the touchpad, do the following:

1. Press * and enter the function number to select the

desired function.

Table 4

lists the programming

information for each function.

Note: Press

*

repeatedly to scroll through available

functions

Table 4. Touchpad functions

Function num ber

Function

0

Adjust touchpad tone

1

Temp master mode

View zone status

2

Service menu

3

View alarm memory

44

Test function

45

Display function

46

Light control for X10

47

House codes for X10

49

Change languages

5

Change user codes

6

Assign user authority

7

Reset function

90

Log review

91

Adjust view /brightness of LCD

92

Program custom messages

93

Set touchpad options

94

Set touchpad number and partition

95

Set elapsed time (in minutes) since last
autotest

97

Set system time and date

98

Call back for dow nload

99

Seize phone line for dow nload

Chime

Walk test

Exit

Silent exit

2. To exit the function menu, press #.

Adjust touchpad tone (0)

To raise or lower the tone on the touchpad, do the following:

1. Enter * 0.

2. Press or to raise or lower the tone. The touchpad will

emit a continuous tone, allowing you to hear the selection.

3. To save the tone and exit, press #.

Temporary master mode (1)

The master mode of operation allows you to temporarily

access any partition (providing your code is authorized) within

the system and to do functions in other partitions. The keypad

will revert back to its assigned partition 60 seconds after a key

press, or 10 seconds without a keypress. To set a temporary

master mode, do the following:

1. Enter * 1.

2. Enter your user code.

3. To exit, press #.

View zone status (p)

To view zone status, do the following:

1. Press * .

2. Press or to scroll through the list. The list shows all

zones in sequential order by zone number.

3. To exit, press #.

Advertising