Interlogix NX-148E User Manual

Page 19

Advertising
background image

NX-148E LCD Keypad

17

IV.

PARTITIONED SYSTEMS OPERATION

This system is

is not

partitioned.

If your system is multi-partitioned and the keypad resides in one partition, your
keypad will provide the status of the zones in your partitioning by using the screen
messages described earlier in this manual. The Master Mode of operation allows you
to temporarily access any partition (providing your code is authorized) within the
system and to perform functions in other partitions. Read this entire manual to help
you understand the different screen messages that will be displayed from your
keypad.

NOTE:

r 1 will temporarily access the Master Mode. The keypad will revert back

to its assigned partition 60 seconds after a keypress, or 10 seconds without a
keypress. Press [#] to exit this mode.

LIGHTS IN PARTITIONING MASTER MODE

ARMED will illuminate if ALL partitions are armed.
READY will illuminate if ALL partitions are "Ready". The ready light will flash if all

areas are Ready or Force armable.

FIRE will illuminate if ANY one area has a Fire condition. The fire light will flash if

ANY area has a Fire Trouble condition.

POWER will illuminate if the primary power is connected to the NX-8 control

panel. It will flash if the system has a low standby battery condition.

STAY will illuminate if ANY area has the stay light on.
CHIME will illuminate if ANY partition is in the "Chime" mode.
EXIT will illuminate if ANY area is timing an exit delay. It will flash if ANY area is in

the last 10 seconds of an exit delay.

BYPASS will illuminate if ANY area has a zone bypassed.
CANCEL will flash if ANY partition is in an abort delay time. If a code is entered

followed by the [CANCEL] key during or after an alarm report, the cancel light will
illuminate and remain constant until the central station has received the cancel
report.

SOUNDER will sound if ANY area has the sounder on. This includes Entry delay,

Exit delay, Chime, and Alarm.


DISPLAYS IN THE PARTITIONING MASTER MODE

ARMED and READY STATUS

The LCD screen will display the Armed and Ready status of ALL eight (8)
partitions if any or all of the areas is armed or not ready.

Advertising