Interlogix NX-148E User Manual

Page 22

Advertising
background image

NX-148E LCD Keypad

20

V.

KEYPAD CONTROL TONES (BEEPS)


A sounder is built into the keypad and may sound for any of the following
reasons:

Beeps for all keypresses.

Sounds a continuous tone during the Entry delay time.

Pulses when a day zone is violated while the system is disarmed.

Pulses when a FIRE zone has a trouble condition.

Pulses when the armed status changes and the AC power is off.

Beeps 3 times for trying to arm with the “READY” light off, if “FORCE

ARMING” has not been selected.

Beeps 1 second for the ‘CHIME” feature.

Beeps 1 second at the end of the exit delay.

Beeps to indicate telephone line fault if selected.

Beeps during an exit delay; beeps rapidly for the last 10 seconds of an

exit delay; and beeps 1 second at the end of the exit delay.

Pulses when one or more of the following conditions are detected: Zone

or Box Tamper, Low Battery, AC Power Fail, or Expander trouble.

Beeps 3 times every minute indicating a low battery or missing

transmitter is detected (if wireless device is in system). Entering code will
suppress the sounder for 12 hours.

Entering a valid code will silence the keypad sounder when it is pulsing. The
arm/disarm state of your system will not change when entering a code to silence a
pulsing keypad sounder. Please contact your installer if a trouble condition exists.

Advertising