Page 2: Before you begin

Advertising
background image

Follow the wire length limits outlined in the specific panel

Installation Instructions between the touchpad and control

panel.

The following must be observed in UL installations

The touchpad hardwire input must not be used for fire

alarm initiating devices.

Only UL-listed devices may be connected to the touchpad

hardwire input.

The touchpad hardwire input can be configured for

normally closed or normally open protection devices.

For UL installations with UltraGard and Concord (software

versions 1.0–1.6) panels, do not use the touchpad

hardwire input.

Tools Needed

• Drill

with

bits

• Screwdrivers

#6 screws and anchors (included)

Panhead screws for a gang box installation

Saw or utility knife for cutting wallboard

Note: Do not use screws larger than #6 or the touchpad

will not seat properly onto the back-plate.

Installation

The touchpad can be installed on a wall or in a gang box.

To mount the touchpad on a wall:

1. Separate the mounting bracket from the back-plate by

loosening the two bottom screws and unlatching the tabs

from the mounting slots (see Figure 1 below).

2. Place the back-plate on the wall and mark the four

mounting holes and the wire access hole (see Figure 2

below). Be sure to leave a 1-inch clearance on all sides of

the back-plate.

3. Drill holes and insert appropriate anchors.

4. Secure the back-plate to the wall with included screws.

5. Cut a hole in the wall where the wire access hole was

marked to pull your cable through.

Figure 1: Touchpad mounting slots

MOUNTING SLOTS

CABLE OPENING

OPENING FOR CONNECTOR

3101G03B.DSF

LOOSEN BOTTOM SCREWS (X2)

To mount the touchpad in a gang box:

1. Separate the mounting bracket from the back-plate by

loosening the two bottom screws and unlatching the tabs

from the mounting slots (see Figure 1 above).

2. Line up the gang box mounting holes with the holes on the

gang box (see Figure 2 below).

3. Secure the back-plate to the gang box with panhead

screws.

Note: Do not overtighten screws or the back-plate may

bind and prevent the touchpad from mounting properly.

Figure 2: Back plate and mounting holes

3101G02B DS4

GANG BOX MOUNTING HOLES (X2)

BACK PLATE MOUNTING TABS (X3)

WALL MOUNTING HOLES (X4)

WIRE

ACCESS

HOLE

Wiring

Wiring consists of connecting the touchpad wiring harness to

the panel terminals. You may also connect an optional

hardwire sensor to the touchpad hardwire input wires.

Before You Begin

1. Disconnect the panel AC power transformer and backup

battery (turn off power switch on UltraGard panels).

2. Run a 4-conductor, 22-gauge wire cable from the panel to

the touchpad location.