Mounting the touchpad, Setting touchpad unit numbers, Power up and bus communication – Interlogix SuperBus 2000 2X20 User Manual

Page 4: First touchpad

Advertising
background image

Figure 5: Wiring the touchpad to Ultragard panels

12

13

14

15

GND

DC

OUT

BUS

B

BUS

A

CONTROL PANEL

NOT

USED

OPTIONAL

SWITCH

WITH MAGNET

YELLOW

BLACK

RED

WHITE
GREEN

WIRING HARNESS

49-430

TAB

SLOT (3)

(Not to be used in UL
listed installations)

SHIELDED

CABLE

C onnect Shield To Earth Ground

Mounting the Touchpad

1. Align the slots on the touchpad with the slots on the back-

plate. Insert the mounting tabs into the mounting slots and

press the keypad toward the wall/gang box.

2. Tighten the two bottom screws.

Setting Touchpad Unit Numbers

Note: In multiple partition systems all new touchpads default to

partition 1. To change partition assignment please see specific

panel Installation Instructions. All partitions must be disarmed

before entering program mode.

Panels automatically assign or learn the unit numbers of each

bus device upon power up or entering programming mode.

SuperBus 2000 panels (Advent panels and Concord panels

with software version 2.0 or newer) automatically assign

different unit numbers to each SuperBus 2000 module.

SuperBus panels (UltraGard panels and Concord panels with

software versions 1.0–1.6) do not automatically assign different

unit numbers to each SuperBus 2000 module. For these

panels, alphanumeric touchpads default to 001. If desired or

necessary, the unit number must be manually changed.

Guidelines for Assigning Alphanumeric Touchpad

Unit Numbers (Concord panels with software

versions 1.0–1.6 and UltraGard panels)

Use the following guidelines to avoid communication conflicts

between bus devices and the panel:

Always start with one touchpad connected to the panel

and make sure it is working properly before connecting

additional touchpads.

Whenever possible, such as in new installations, assign

alphanumeric touchpad unit numbers before beginning all

other panel programming.

Other bus devices with device unit number DIP switches

(ESM, HIM, etc.) must be set to the desired unit number

before applying power and entering program mode.

Power Up and Bus Communication

Powering up Concord Panels with Software Version

2.0 or Newer and Concord Express/Concord Ultra

Panels

1. Verify that all wiring between the panel and touchpad is

correct.

2. Connect the panel battery and plug in the panel

transformer. Alphanumeric touchpads show “SCANNING

BUS DEVICES,” then a date and time display.

3. Verify correct operation by pressing *. The display should

show the current system status.

Note: If after pressing * the touchpad does not display the

current system status, see “Troubleshooting.”

Powering up Concord Panels with Software Versions

1.0–1.6

First Touchpad

1. Verify that all wiring between the panel and touchpad is

correct.

2. Check the unit number DIP switches on all other bus

devices (ESM, HIM, etc.) and make note of their

respective unit numbers.

Note: Touchpads default to unit number 001 when first

installed. If possible, leave this unit number open. If unit

number 001 is not available, or there are multiple

touchpads installed see the section “Additional

Touchpads” below.

3. Connect the panel battery and plug in the panel

transformer. Alphanumeric touchpads show “SCANNING

BUS DEVICES,” then a date and time display.

4. Verify correct operation by pressing *. The display should

show the current system status.

Note: If after pressing

*

the touchpad does not display the

current system status, see “Troubleshooting” on page 7.

4

SuperBus 2000 2X20 LCD Alphanumeric Touchpad Installation Instructions