Wiring panels, Concord/concord express/concord ultra panels, Advent panels – Interlogix SuperBus 2000 2X20 User Manual

Page 3: Ultragard panels

Advertising
background image

3. Splice the 4-conductor cable wires to the matching colored

wires located on the touchpad wiring harness.

Find your panel in the next section for specific wiring

instructions.

Wiring Panels

Concord/Concord Express/Concord Ultra Panels

1. Connect the touchpad wiring to the panel terminals as

shown in Figure 3 below. Wire multiple touchpads in

parallel.

2. If desired, connect an optional hardwire switch to the

yellow touchpad wires as shown in Figure 3 below.

Concord Express Systems- Wire a 2K ohm EOL resistor

(49-467) in series with normally closed switches and in

parallel with normally open switches (see Figure 3 below).

Concord Systems with software version 2.0 or newer-

Wire a 2K ohm EOL resistor (49-467) in series with

normally closed switches and in parallel with normally

open switches (see Figure 3 below).

Concord Systems with software versions 1.0–1.6 - This

switch must be unsupervised and a resistor must not be

used.

Note: The optional touchpad hardwire input must be

added to panel memory. See the Concord/Concord

Express panel Installation Instructions for setting the

configuration.

3. Insert the touchpad wiring harness connector onto the pins

located on the rear of the unit. Make sure the yellow wires

are to the left, as shown.

Figure 3: Wiring the touchpad to Concord and Concord Express
panels

3

4

5

6

GND

+12V

BUS

BUS

B

BUS

A

PANEL TERMINALS

NOT

USED

OPTIONAL

N/C SWITCH

WITH MAGNET

YELLOW

BLACK

RED

WHITE

GREEN

TOUCHPAD

WIRING HARNESS

49-430

TAB

SLOT (3)

OPTIONAL

N/O SWITCH

WITH MAGNET

2K OHM

EOL RESISTOR

(Concord 2.0 or later

and Concord

Express panels)

SHIELDED

CABLE

Connect Shield
to Earth Ground

Advent Panels

1. Splice the touchpad wiring to the panel SuperBus wiring

harness as shown in Figure 4 below. Wire multiple

touchpads in parallel.

2. If desired, connect an optional hardwire switch to the

yellow wires on the touchpad wiring harness. Wire a 2K

ohm EOL resistor (49-467) in series with normally closed

switches and in parallel with normally open switches (see

Figure 4 below).

Note: The optional touchpad hardwire input must be

added to panel memory. See the Advent panel Installation

Instructions for setting the configuration.

3. Insert the touchpad wiring harness connector onto the pins

located on the rear of the unit. Make sure the yellow wires

are to the left (see Figure 4 below).

Figure 4: Wiring the touchpad to Advent panels

NOT
USED

YELLOW

TOUCHPAD

WIRING HARNESS

49-430

SPLICE

PANEL SUPERBUS

WIRING

HARNESS 49-462

BL

ACK (

G

ND)

WHI

T

E

(

B

US

B)

GREE

N (

B

US

A)

RED (

+

1

2

VDC)

TO ADDITIONAL

SUPERBUS

TOUCHPADS

AND/OR

MODULES

TAB

SLOT (3)

OPTIONAL

N/C SWITCH

WITH MAGNET

2K OHM

EOL RESISTOR

OPTIONAL

N/O SWITCH

WITH MAGNET

Connect Shield
to Earth Ground

SHIELDED

CABLE

UltraGard Panels

1. Connect the touchpad wiring to the panel terminals as

shown in Figure 5 on page 4. Wire multiple touchpads in

parallel.

2. If desired, connect an optional hardwire switch to the

yellow touchpad wires as shown in Figure 5 on page 4

(unsupervised in UltraGard systems).

Note: The optional touchpad hardwire input must be

added to panel memory. See the UltraGard panel

Installation Instructions or Reference Manual for setting

the configuration.

3. Insert the touchpad wiring harness connector onto the pins

located on the rear of the unit. Make sure the yellow wires

are to the left

SuperBus 2000 2X20 LCD Alphanumeric Touchpad Installation Instructions

3

Advertising