Software controlled store/recall cycle, Switching waveforms – Cypress CY14B101NA User Manual

Page 13

Advertising
background image

PRELIMINARY

CY14B101LA, CY14B101NA

Document #: 001-42879 Rev. *B

Page 13 of 25

Software Controlled STORE/RECALL Cycle

Parameters

[27, 28]

Description

20 ns

25 ns

45 ns

Unit

Min

Max

Min

Max

Min

Max

t

RC

STORE/RECALL Initiation Cycle Time

20

25

45

ns

t

SA

Address Setup Time

0

0

0

ns

t

CW

Clock Pulse Width

15

20

30

ns

t

HA

Address Hold Time

0

0

0

ns

t

RECALL

RECALL Duration

200

200

200

µs

Switching Waveforms

Figure 12. CE and OE Controlled Software STORE/RECALL Cycle

[28]

Figure 13. Autostore Enable / Disable Cycle

t

RC

t

RC

t

SA

t

CW

t

CW

t

SA

t

HA

t

LZCE

t

HZCE

t

HA

t

HA

t

HA

t

DELAY

t

STORE

/t

RECALL

t

HHHD

t

LZHSB

High Impedance

Address #1

Address #6

Address

CE

OE

HSB (STORE only)

DQ (DATA)

RWI

t

RC

t

RC

t

SA

t

CW

t

CW

t

SA

t

HA

t

LZCE

t

HZCE

t

HA

t

HA

t

HA

t

DELAY

Address #1

Address #6

Address

CE

OE

DQ (DATA)

t

SS

Notes

27. The software sequence is clocked with CE controlled or OE controlled reads.
28. The six consecutive addresses must be read in the order listed in

Table 2

on page 5. WE must be HIGH during all six consecutive cycles.