2-4

Catalyst 2975 Switch Hardware Installation Guide

OL-17784-01

Chapter 2 Switch Installation

Preparing

Warning

Voltages that present a shock hazard may exist on Power over Ethernet (PoE) circuits if
interconnections are made using uninsulated exposed metal contacts, conductors, or terminals.
Avoid using such interconnection methods, unless the exposed metal parts are located within a
restricted access location and users and service people who are authorized within the restricted
access location are made aware of the hazard. A restricted access area can be accessed only through
the use of a special tool, lock and key or other means of security.
Statement 1072

Warning

No user-serviceable parts inside. Do not open. Statement 1073

Warning

Installation of the equipment must comply with local and national electrical codes. Statement 1074

Caution

To comply with the Telcordia GR-1089 Network Equipment Building Systems (NEBS) standard for
electromagnetic compatibility and safety, connect the Ethernet cables only to intrabuilding or
nonexposed wiring or cabling.

Caution

To comply with the Telcordia GR-1089 NEBS standard, PoE or non-PoE 10/100/1000 Ethernet port
cables that exit from either the left side or right side of the switch should be routed and tied to the nearest
rack metal hardware.

Note

The grounding architecture of this product is DC-isolated (DC-I)