Laars heating systems, Partie (canadian electrical, Figure 13. wire connection diagram – LAARS Pennant PNCV (Sizes 200, 300, 400) - Install and Operating Manual User Manual

Page 24

Advertising
background image

LAARS Heating Systems

Page 22

Pennant 200, 300, 400

Page 23

AVERTISSEMENT

L’appareil doit être relié à la terre conformément

aux exigences de la réglementation locale ou,

en l’absence d’une telle réglementation, à la plus

récente édition du National Electrical Code (Code

national de l’électricité) ANSI/NFPA 70 aux États-

Unis, et à la plus récente édition du Code Canadien

de l’électricité 1

ère

partie (Canadian Electrical

Figure 13. Wire Connection Diagram

L1

L2

P1

P2

1

2

3

4

6

POWER SUPPLY, HOT LEG,

115/230VAC SINGLE PHASE

FIELD-SUPPLIED OR FACTORY-MOUNTED

PUMP, 120VAC 1HP MAX, 230VAC 3/4HP MAX

115VAC HOT

115VAC NEUTRAL

TRANSFORMER

TIME DELAY

RELAY, K1

BK

TEMPERATURE CONTROL

IGNITION CONTROL

POWER

CALL

FOR

HEAT

AIR

FLOW

HIGH

LIMIT

STAGE 1

STAGE 2

WATER

FLOW

REMOTE

LED BOARD

F1 F2

24

VAC

FV+ FV-

S1

120 L1 L2

S2

FS

TH PSW

GND

VAL

240

1

2

3

4

5

6

5
4
3
2
1

BLOWER

9
8
7
6
5
4
3
2
1

R

R

Y

G

THERMISTOR #1

IGNITER

2AMP

FUSE

LOCAL/REMOTE

SWITCH

BK

BK

R

BL

LWCO

JUMPER

OTHER INTERLOCKS

JUMPER

THERMISTOR #2

DRY REMOTE

ALARM CONTACTS,

CLOSE ON ALARM

AIR FLOW

BLOCKED

VENT

SWITCH

MV
MV

MV
MV

REMOTE TEMPERATURE

CONTROL, CONNECT TO

DRY CONTACTS ONLY

BR

BR

V

GY

R

Y

R

Y

R

Y

Y
R

BR

R
O

BK/Y

V

GY

BL

BL

Y

BR

BL

GY

V

W

BK

GY

BK

W

G

W

G

BK

Y

Y

V

Y

R

R

BK

BL

GY

BL

ON/OFF

SWITCH

LED

LED

LED

LED

LED

LED

LED

LED

LED

1

2

3

4

5

6

7

8

9

10

11

12

1

2

3

4

COM

COM

NO

NC

1

2

G

8
7
6
5
4
3
2
1

3
2
1

BK

G

V

GY

R

Y

Y

Y

Y

P

GY

V

BR

BR

V

BL/W

Y

GY

BR

BL/W

BL/W

GY

GY

BL

BL

BL

BR

BR

BL

O

O

BR

BL

R

R

O

BL

REMOTE

LOCAL

COM

R

Y

Y

Y

R

R

BK

BK

BK

R

W

BK

W/R

W/BK

K2

BK/Y

-/4

R

+/5

COM

NC

Y

R

BK/Y

FLOW

SWITCH

HIGH

LIMIT

FUSIBLE LINK

(200 ONLY)

BK/Y

V

BL/W

NO

COM

1

P

BR

BL/W

P

P7

P1

P2

CPU

P3

AUXILLIARY

(CONTROL LOOP 2)

CONTACT CLOSURE

STAGE 1

STAGE 2

(2-STAGE

UNITS ONLY)

AUXILLARY

ALARM

M

VALVE

STAGE 1

VALVE

STAGE 2

(2-STAGE

UNITS ONLY)

POWER SUPPLY, NEUTRAL LEG,

115/230VAC SINGLE PHASE

BLK - BLACK

BK/Y - BLACK WITH YELLOW

TRACE

BL

- BLUE

BL/W - BLUE WITH WHITE

TRACE

BR

- BROWN

G

- GREEN

GY

- GRAY

O

- ORANGE

P

- PINK

R

- RED

V

- VIOLET

W

- WHITE

Y

- YELLOW

115V FIELD WIRED

115V FACTORY WIRED

24V FIELD WIRED

24V FACTORY WIRED

INTERNAL CIRCUITRY

BK

BK

W

W

Code Part 1) CSA C22.1, au Canada. N’utilisez

pas les tuyauteries d’eau ou de gaz pour mettre

à la terre les pièces métalliques de la chaudière;

des tuyauteries en plastique ou des raccords

union diélectriques peuvent isoler électriquement

la chaudière. Les employés qui sont appelés à

travailler sur la chaudière ou autour peuvent être

électrocutés par une chaudière qui n’est pas mise à

la terre.

Advertising
This manual is related to the following products: