Keyboard – Compaq AP500 User Manual

Page 103

Advertising
background image

4-27

Compaq Professional Workstation AP500 Maintenance and Service Guide

Memory

Table 4-14

Memory Test Error Codes

Error Code

Description

Recommended Action

200-xx

Memory machine ID test failed.

Insert DIMM in the correct location.

202-xx

Memory system ROM checksum failed.

The following steps apply to error codes 202-xx through

215-xx:

203-xx

Memory write/read test failed.

1. Remove one pair of DIMM at a time until the error

message stops.

204-xx

Memory address test failed.

2. Replace other removed DIMMs one pair at a time,

testing each to ensure the error does not return.

211-xx

Random pattern test failed.

3. Replace the system board and retest.

214-xx

Noise test failed.

215-xx

Random address test failed.

Keyboard

Table 4-15

Keyboard Test Error Codes

Error Code

Description

Recommended Action

300-xx

Keyboard ID test failed.

The following steps apply to error codes 300-xx through

304-xx:

301-xx

Keyboard self-test/interface test failed.

1. Check the keyboard connection. If disconnected, turn

the computer off and connect the keyboard.

302-xx

Individual key test failed.

2. Replace the keyboard and retest.

304-xx

Keyboard repeat test failed.

3. Replace the system board and retest.

Advertising