Compaq Professional Workstation AP500 Maintenance and Service Guide

POST Messages

Continued

Message

Beeps*

Probable Cause

Recommended Action

605-Diskette Drive Type

Error

2S

Mismatch in drive type

Run Computer Setup or Windows NT

utilities.

611-Primary Floppy Port

Address Assignment Conflict

2S

Configuration error

Run Computer Setup or Windows NT

utilities.

1151-System Board COM Port

1 Address Assignment Conflict

2S

Both external and internal serial

ports are assigned to COM1

Run Computer Setup or Windows NT

utilities.

1152-System Board COM Port

2 Address Assignment Conflict

2S

Both external and internal serial

ports are assigned to COM2

Run Computer Setup or Windows NT

utilities.

1155-COM Port Address

Assignment Conflict

2S

COM port address conflict

Run Computer Setup or Windows NT

utilities.

1610-Temperature Violation

Detected

None

The system is too hot.

Turn off the workstation and let it cool off.

If the condition persists, run Diagnostics to

get more information.

1611-Fan Failure Detected

None

The fan is not operating properly. Run Diagnostics to get more information.

Replace the fan.

1720-IntelliSafe Hard Drive

Detects Imminent Failure

None

IDE hard drive(s)

Back up contents and replace hard drive.

1720-SMART Hard Drive

Detects Imminent Failure

None

SCSI hard drive(s)

Back up contents and replace hard drive.

1771-Primary Disk Port

Address Assignment Conflict

2S

Internal and external IDE hard

drive controllers are both

assigned to the primary address.

Run Computer Setup or Windows NT

utilities.

1772-Secondary Disk Port

Address Assignment Conflict

2S

IDE Configuration

Run Computer Setup.

1780-Disk 0 Failure

None

IDE hard drive failure

Run Computer Setup.

1781-Disk 1 Failure

None

IDE hard drive failure

Run Computer Setup.

1782-Disk Controller Failure

None

IDE configuration failure

Run Computer Setup.

1790-Disk 0 Failure

(Secondary)

None

IDE hard drive failure

Run Computer Setup.

1791-Disk 1 Failure

(Secondary)

None

IDE hard drive failure

Run Computer Setup.

1792-Secondary Disk

Controller Failure

None

IDE circuitry failure

Run Computer Setup.

Continued