Serial connection, Definition of dip switches – Longshine LCS-844MT User Manual

Page 20

Advertising
background image

16

Serial Connection


This Device Server features DIP switches on the rear
panel that sets the unit to the correct type of cable
configuration to support

connection with a RS-232 /

422 / 485 device.

Definition of DIP Switches

No

Dip description

Default

1

ON: Console / OFF: Data

OFF

2 RS-232

ON

3

RS-422 / 485 (4W)

OFF

4 RS-485

(2W)

OFF

5 NA

OFF

6 NA

OFF

7 TMR

(Terminator)

OFF

For setting the control function of the serial port, see
the table below:

DIP 1

Serial Connection

ON RS-232

Console

OFF Data

Communication

NOTE:

1.

If using console mode turn the DIP Switch 1 to ON position.
For data communication from the serial device keep the switch
to OFF position. In case of ON position data communication
will be blocked and at OFF position console port access.

2.

For some RS-422/485 devices, which may not be designed to
provide DB-9 connection, please check the pin definition to
connect the devices.

3.

For the first time installation, you have to use console mode to
setup the IP and TCP port configuration with RS-232 cable.

Advertising