transfer mode option for the Device Server, move the
DIP Switch 1 to OFF position.

You can assign the TCP port number to monitor and
access the serial device via device server over the
network/Internet from a workstation using Serial IP
Redirector software. (The TCP port number can be of
any number from 1024 to 65535).

RS-232/422/485 Transfer Configuration

In case you are using a serial device with 2-wire RS-
485 application or Modbus RTU protocol, do not forget
to “Enable” Packet mode of serial input. Also put
appropriate inter-packet timeout value to allow the
smooth data communication.
To add the time-out value via console mode, first
Enable” the packet mode and “Save” the settings.
Once settings applied, you will be able to change the
timeout value.