Table 5-5: compensation features – Maxim Integrated 71M6534 Energy Meter IC Family Software User Manual
Page 48

71M653X Software User’s Guide
Feature
Code
Size
1
φ
3
φ
Description
Chopping of
VREF
0.06KB
Y
Y
Control of the chopping bit
Temperature
compensation of
VREF
0.1KB Y
Y
Digital
compensation
using the GAIN_ADJ input of
the CE, based on linear and quadratic temperature
coefficients
RTC compensa-
tion using mains
frequency
0.2KB N/opt N/opt
Optional
compensation of RTC by counting cycles on
mains.
Correction does not occur when frequency
measurement is inhibited by low voltages.
Full RTC
compensation
0.2KB Y
Y
2nd-order compensation of RTC to 4ppm, using
temperature. Temperature based correction does not
occur when the ADC mux is off-line.
Temperature
measurement
0.0K
Y
Y
Provides difference from calibration temperature to
precision of 0.1 C when calibrated
Table 5-5: Compensation Features
Code
Size
1
φ
3
φ
Description
Feature
Wh imports
Y
Y
Standard option of milliwatt hours, “999.999”
Pulse output for
Wh imports
0.23KB
Y
Y
Standard option of 1 kh/pulse on both DIO 6 and DIO
2.
VAn pulse output
0.25KB
Y
Y
Volt-amperes, 1 kh/pulse
Wh equation 0
0.2KB
N/opt
N
1 element 2 wire
Wh equation 1
0.2KB
N/opt
N
1 element 3 wire
Wh equation 2
0.2KB
Y
N
2 element 3 wire delta
Wh equation 3
0.2KB
N
N/opt
2 element 4 wire delta
Wh equation 4
0.2KB
N
N/opt
2 element 4 wire wye
Wh equation 5
0.2KB
N
Y
3 element 4 wire wye
Frequency
register
0.1KB
Y
Y
Inhibited if freq > 70Hz or voltage is below the
threshold
Wh export register 0.25KB
Y
Y
Wh exported, display reads “999.999”
Wh export pulse
output
0.25KB
Y
Y
Wh exported, display reads “999.999”
VARh signed
register
0.1KB
Y
Y
Used for autocalibration, and power factor
calculations.
VARh import
register
0.4KB Y
Y
VARh import
pulse output
0.25KB Y
Y
v1.1v1.1
TERIDIAN Proprietary
48 of 116
© Copyright 2005-2008 TERIDIAN Semiconductor Corporation