2 recommended configuration – Maxim Integrated 78M6610+PSU Hardware Design Guidelines User Manual

Page 2

Advertising
background image

78M6610+PSU Hardware Design Guidelines

AN_6610_107

2

Rev 0

2 Recommended Configuration

Resistive current shunts and voltage dividers are commonly used to meet system limitations on size and
cost. When using a shunt current sensor, the measurement IC and its power domain are directly
connected to AC mains. In this case, the 78M6610+PSU measurement device is typically powered
through an auxiliary winding of the SMPS transformer (generally the stand-by channel). To protect the
auxiliary winding from surge events and avoid switching noise from being conducted onto AC mains, the
resistive sensors are located behind the EMI filter.

The system communicates with the 78M6610+PSU across data isolators (i.e. opto-couplers or digital
isolators) as the host controller is located on the secondary side and often referenced to earth ground.
The UART interface is suggested for lowest cost of data isolation.

78M6610+PSU

LDO

ISOLATED

GROUND

ISOLATED

GROUND

SMPS

TRASFORMER

AC

INLET

To PFC

TX

RX

HOST

PROCESSOR

CHASSIS

EARTH

GROUND

SYSTEM GROUND

GALVANIC ISOLATION

OPTO-

COUPLERS

GALVANIC

ISOLATION

EARTH

GROUND

LINE

NEUTRAL

Figure 1: Typical Implementation of 78M6610+PSU