2.1 Sensor Connections

The basic connections for a shunt-based system are represented below.

Shunt

NEUTRAL

LINE

750

AVN

INPUT

750

AVP

NTC

ATEMP

100

nF

1000

pF

1000

pF

100

nF

750

1000

pF

100

nF

AIP

AIN

1M

1M

100

nF

LOAD

78M6610+PSU

V

3P3

V

3P3

V

3P3

Figure 2: Basic Connection Diagram on Shunt-Based Systems


The 78M6610+PSU makes use of a single 3.3 VDC supply (V

3P3

) that also represents the reference

potential for the following analog inputs:

• AVP/AVN used to measure the line voltage.
• AIP/AIN used to measure the current.
• ATEMP1 and ATEMP2 used to measure external temperature.


Do not tie the ground of the 78M6610+PSU directly to earth ground when using shunts. See
the Safety Precautions section.