AN_6610_107

78M6610+PSU Hardware Design Guidelines

Rev. 0

7

3 Alternate Configuration

Voltage and current sensors can alternatively be located right at the AC inlet in front of the EMI filters if
using a current transformer (CT). In this configuration, the measurement device is powered using the
same auxiliary winding from the standby channel, but with a high impedance path between
78M6610+PSU circuitry and AC mains.

I Load

I Secondary

AIN

AIP

750

V

3P3A

750

100n

100n

1000p

1000p

RBurden

CT

78M6610+PSU

10K

10K

AVP

AVN

750

100n

100n

1000p

1000p

750

INLET

LOAD

1M

1M

1M

1M

V

3P3

V

3P3

Neutral

(or Line)

Line

(or Neutral)

Figure 3: Pseudo-Isolated Configuration Example


It is highly recommended to use high-tolerance resistors in the voltage divider to minimize measurement
error caused by divider ratio mis-matching.