Automatic Gain Calibration:

Before tuning the gain setting, the dead zone for that function must be tuned. If the dead
zone tuning has not been completed, follow the instructions for tuning a dead zone.

Follow Section 8.1.1 (level booms, working RPM, etc.) before proceeding.

Ensure the UC4.5 control panel is in manual mode, at the run screen.

Navigate to the "More?" menu prompt in the SETUP (

) menu. Press

to confirm.

Navigate to the boom section to be setup, for example, "Left?" to adjust the left up and/or
the left down settings. Press the

button to confirm.

Press the

button to access the next menu prompt. Choose the gain up or down setting

(Figure 10).

Press and hold the

button.

When the "Done" message is displayed, release the

button to view the new setting.

Manual Gain Calibration:

CAUTION

This test will drive the boom at full speed in the selected direction for one second.
Make sure the boom has full range of movement and if driving the boom down,
make sure it is not close to the ground.

The purpose of this test is to determine the sprayer boom speeds. It is recommended that
each test be performed three times and the readings averaged.

From the speed measurements taken, use Table 2 to determine the appropriate gain values
to use for each function. This test will provide approximate results for gain values. Proper
gain values rely on more than just boom speed so it is highly recommended to use the
automatic gain setup if possible.

Follow Section 8.1.1 (level booms, working RPM, etc.) before proceeding.

Ensure the UC4.5 control panel is in manual mode, at the run screen.

Navigate to the "More?" menu prompt in the SETUP (

) menu. Press

to confirm.

Navigate to the boom section to be setup, for example, "Left?" to adjust the left up and/or
the left down settings. Press the

button to confirm.

Press the

button to access the next menu prompt. Choose the gain up or down setting

(Figure 10).

Press and hold the

button.

The valve will turn on at 100 percent speed for exactly one second, regardless of what the
gain setting already is. The screen will show the actual change in height.