The change in height reading is live as long as the

button is held. Wait until the height

reading has settled to a stable value and record this reading. This is the boom speed in
inches per second (in/s) or mm per second (mm/s).

•

Repeat the Manual Gain Test three times, repositioning the boom as necessary.

•

Average the three readings. Typical values are between 15 and 50 inches/sec.

•

Set the Gain value using the

buttons using the tables below as a guideline. Right and

left gain settings are polarized for direction as shown in Table 2.

Note: Gain values depend on many more factors than just speed, and therefore are best set
automatically or by an experienced operator.

Note: Test the system in automatic mode at a sensitivity setting of five. The sensitivity setting will scale
the gain settings. If the booms are not reacting quickly enough, a higher gain setting will make the
boom respond faster. If the booms are too jerky or unstable, use a lower the gain setting or improve the
boom’s mechanical damping.

Table 2: Gain Settings

Function

Boom Speed (inch /

sec)

Up Gain

Down Gain

Left / Right

1 - 5

Too Slow

Too Slow

Left / Right

5 - 15

225 - 175

100 - 70

Left / Right

15 - 25

175 - 150

70 - 50

Left / Right

25 - 40

150 - 100

50 - 30

Left / Right

40 - 70

100 - 50

30 - 15

Left / Right

70 +

50 - 1

15 - 1

Main (on / off)

1 - 5

100 - 75

100 - 75

Main (on / off)

5 - 10

75 - 50

75 - 50

Main (on / off)

10 - 15

50 - 30

50 - 30

Main (on / off)

15 - 20

30 - 15

30 - 15

Main (proportional)

1 - 5

85 - 75

85 - 75

Main (proportional)

5 - 10

75 - 66

75 - 66

Main (proportional)

10 - 15

66 - 60

66 - 60

Main (proportional)

15 - 20

60 - 53

60 - 53

Roll

1 - 10

254 - 225

254 - 225

Roll

10 - 15

225 - 175

225 - 175

Roll

15 - 20

175 - 150

175 - 150

Roll

20 +

150 - 100

150 - 100