Controller Active and Standby

Controller Active and Standby

The Axxius 800 can function fully with a single Controller card, however Controller
redundancy is available with two like Controllers (DS1 or DS3) installed. When two
Controllers are installed in a system, one is always Active and the other is Standby. The
Standby can have 2 conditions:

l

Hot Standby - meaning that the card is ready to take over for the active and the
switch will not affect service

l

Cold Standby - meaning that the card is ready to go active (healthy) but for some
reason (code of the 2 controllers is not the same) it will need to reconfigure the
box when it goes active, which will be service affecting.

There are two ways to identify the status of the Controllers.

1. CLI Command status equipment

> status equipment

CardType Status SW Vers CLEI

SLOT P1 +24 V Healthy SIPUMR0DAA

SLOT P2 Card not installed

SLOT A1 T1x4 Active 1.1.0 SIIX4W0DAA

SLOT A2 T1x4 Hot Standby 1.1.0 SIIX4W0DAA

SLOT B1 Card not installed

SLOT B2 Card not installed

SLOT 1 TSRx4 Present 1.00 NOT AVAIL

SLOT 2 T1x4 Present 1.73 SIIXFWBDAA

SLOT 3 V35x2 Present 2.01 SIC3HK0CAA

SLOT 4 V35x2 Present 2.01 SIC3HK0CAA

SLOT 5 BRIx8 Present 1.11 SIIXUX0DAA

SLOT 6 OCUDPx1 Present 1.01 SIIXA4DDAA

SLOT 7 FXOx8 Present 1.12 SIIXPV0DAA

SLOT 8 FXSPSMx1 Present 0.01

SLOT 9 Card not installed

2. Visually looking at the Controller cards.

Active - STAT LED will be solid green.
Hot Standby - STAT LED will be solid yellow
Cold Standby - STAT LED will be flashing yellow