Adder 10, Firestat 10, Ambient limit control 10 – Reznor SDH Parts Manuals User Manual
Page 10: Sensor 10, Smoke detector 10, Position switch 10, Electrical components (cont’d)

Form P-PREEVA, P/N 263985R7, Page 10
CODE 64 - Safety Door
Switch used on Gas/
Control Door on all
Model SDH units and
the Blower Door on any Unit
with Option UV2, Ultra-Violet Light
(See page 26.), P/N 217262
CODE 65 - Two-
Position Switch,
P/N 101902
CODE 66 - Firestat,
P/N 42782
CODE 62 - Convenience
Outlet (Option BC2)
P/N 96912, GFI Outlet
P/N 209010,
Outlet
Cover
CODE 63 - Lock-
able Service Switch
(Option BA6)
See P/N’s below for
Model PEH or REH.
Electrical
Components (cont’d)
-
Apply to models as noted.
Field Connection Panel
(See illustration
on left for location and pages 34-40 for
P/Ns.)
Field Connection Panel (See illustration
on left for location and pages 34-40
for P/Ns.)
CODE 63 (includes all four
pieces in this exploded view)
CODE 42 - Outlet
Cover, P/N 209010
Hole Plug,
P/N 16452 (2)
Hole Plug,
P/N 16451 (2)
CODE 62 - GFI
Outlet, P/N 96912
Box
Field Connection Panel with Optional Service Disconnect
Switch (Option BA6) and/or Convenience Outlet (Option BC2)
Hole Plug,
P/N 16452 (2)
Hole Plug,
P/N 16451 (2)
Cover Plate,
P/N 209001
Cover Plate, P/N 209001
Field Connection Panel without Optional
Service Disconnect Switch and/or Convenience
Outlet has one or two cover plates.
Field Connection Panel
with Cover Plates or
Locations of Optional
Components
CODE 67 - High Ambient
Limit Control, P/N 126170
-
(Option BN2)
CODE 63 - Lockable Service Switch (Option BA6) for Electric Heat Models PEH and REH
Model Size
10A
20A
40A
15B
30B
60B
30D
60D
90D
120D
40E
80E
120E
208/1 (AK2)
205907 207678
N/A
205908 207679
N/A
207679
N/A
N/A
N/A
N/A
N/A
N/A
230/1 (AK3)
205908 207679
N/A
207678 207679
N/A
207679
N/A
N/A
N/A
N/A
N/A
N/A
208/3 (AK5)
N/A
205907 207678
N/A
205908 207679 205908 207679 222422
N/A
207678 207679
N/A
230/3 (AK6)
N/A
205907 207679
N/A
207678 207679 207678 207679
N/A
N/A
207679 222422
N/A
460/3 (AK7)
N/A
205906 205907
N/A
205906 205908 205906 205908 207679 207679 205907 207678 207679
575/3 (AK8)
N/A
205906 205906
N/A
205906 205908 205906 205908 207678 207679 205906 207678 207679
CODE 71 - Duct Smoke Detector,
P/N 159553 (installed in supply
ductwork)
CODE 68 - Ductstat, P/N 115848,
J/C A350 (Opt AG 15, 16, 61, 62)
CODE 69 - Stage Adder, P/N 115849,
J/C S350 (Opt AG 15, 16, 61, 62)
CODE 70 - Display Module, P/N
115852, J/C D350 (Opt AG 16, 62)
CODE 68A - Sensor, P/N 115851
CODE 68 | CODE 69 | CODE 70
(For sensor holder, see
CODE 36, pg 6.)
Sampling Tube, P/N 259069
CODE Description
Applies to
P/N
65 2-position Switch, DPST (Opt AG 3, 15, 16, 61, 62)
All Models
101902
66 Firestat (Option BD4 mounted in the Mixing Box or Option
BD5 field installed in the discharge duct)
All Models
42782
67 High Ambient Limit Control (Heat Cutoff), Option BN2,
Adjustable 0-100°F
All Models
126170
68 Ductstat Control, J/C A350 (Opt AG 15, 16, 61, 62)
PDH/SDH/
RDH/SHH/
RHH
115848
68A Sensor only for CODE 68, #A99BC-25C
115851
69 Ductstat Stage Adder, J/C S350 (Opt AG 15, 16, 61, 62)
115849
70 Digital Display Module, J/C D350 (Opt AG 16, 62)
115852
71 Duct Smoke Detector (Option SA1, in supply duct))
159553