Adder 10, Firestat 10, Ambient limit control 10 – Reznor SDH Parts Manuals User Manual

Page 10: Sensor 10, Smoke detector 10, Position switch 10, Electrical components (cont’d)

Advertising
background image

Form P-PREEVA, P/N 263985R7, Page 10

CODE 64 - Safety Door

Switch used on Gas/

Control Door on all

Model SDH units and

the Blower Door on any Unit

with Option UV2, Ultra-Violet Light

(See page 26.), P/N 217262

CODE 65 - Two-

Position Switch,

P/N 101902

CODE 66 - Firestat,

P/N 42782

CODE 62 - Convenience

Outlet (Option BC2)

P/N 96912, GFI Outlet

P/N 209010,

Outlet

Cover

CODE 63 - Lock-

able Service Switch

(Option BA6)

See P/N’s below for

Model PEH or REH.

Electrical

Components (cont’d)

-

Apply to models as noted.

Field Connection Panel

(See illustration

on left for location and pages 34-40 for

P/N’s.)

Field Connection Panel (See illustration

on left for location and pages 34-40

for P/N’s.)

CODE 63 (includes all four

pieces in this exploded view)

CODE 42 - Outlet

Cover, P/N 209010

Hole Plug,

P/N 16452 (2)

Hole Plug,

P/N 16451 (2)

CODE 62 - GFI

Outlet, P/N 96912

Box

Field Connection Panel with Optional Service Disconnect

Switch (Option BA6) and/or Convenience Outlet (Option BC2)

Hole Plug,

P/N 16452 (2)

Hole Plug,

P/N 16451 (2)

Cover Plate,

P/N 209001

Cover Plate, P/N 209001

Field Connection Panel without Optional

Service Disconnect Switch and/or Convenience

Outlet has one or two cover plates.

Field Connection Panel

with Cover Plates or

Locations of Optional

Components

CODE 67 - High Ambient

Limit Control, P/N 126170

-

(Option BN2)

CODE 63 - Lockable Service Switch (Option BA6) for Electric Heat Models PEH and REH

Model Size

10A

20A

40A

15B

30B

60B

30D

60D

90D

120D

40E

80E

120E

208/1 (AK2)

205907 207678

N/A

205908 207679

N/A

207679

N/A

N/A

N/A

N/A

N/A

N/A

230/1 (AK3)

205908 207679

N/A

207678 207679

N/A

207679

N/A

N/A

N/A

N/A

N/A

N/A

208/3 (AK5)

N/A

205907 207678

N/A

205908 207679 205908 207679 222422

N/A

207678 207679

N/A

230/3 (AK6)

N/A

205907 207679

N/A

207678 207679 207678 207679

N/A

N/A

207679 222422

N/A

460/3 (AK7)

N/A

205906 205907

N/A

205906 205908 205906 205908 207679 207679 205907 207678 207679

575/3 (AK8)

N/A

205906 205906

N/A

205906 205908 205906 205908 207678 207679 205906 207678 207679

CODE 71 - Duct Smoke Detector,

P/N 159553 (installed in supply

ductwork)

CODE 68 - Ductstat, P/N 115848,

J/C A350 (Opt AG 15, 16, 61, 62)

CODE 69 - Stage Adder, P/N 115849,

J/C S350 (Opt AG 15, 16, 61, 62)

CODE 70 - Display Module, P/N

115852, J/C D350 (Opt AG 16, 62)

CODE 68A - Sensor, P/N 115851

CODE 68 | CODE 69 | CODE 70

(For sensor holder, see

CODE 36, pg 6.)

Sampling Tube, P/N 259069

CODE Description

Applies to

P/N

65 2-position Switch, DPST (Opt AG 3, 15, 16, 61, 62)

All Models

101902

66 Firestat (Option BD4 mounted in the Mixing Box or Option

BD5 field installed in the discharge duct)

All Models

42782

67 High Ambient Limit Control (Heat Cutoff), Option BN2,

Adjustable 0-100°F

All Models

126170

68 Ductstat Control, J/C A350 (Opt AG 15, 16, 61, 62)

PDH/SDH/

RDH/SHH/

RHH

115848

68A Sensor only for CODE 68, #A99BC-25C

115851

69 Ductstat Stage Adder, J/C S350 (Opt AG 15, 16, 61, 62)

115849

70 Digital Display Module, J/C D350 (Opt AG 16, 62)

115852

71 Duct Smoke Detector (Option SA1, in supply duct))

159553