Id plug 4, Code 2 and 14 - plug-in relay, omron – Reznor SDH Parts Manuals User Manual
Page 4

Form P-PREEVA, P/N 263985R7, Page 4
Electrical Components (cont’d) - See control compartment illustration on page 3.
CODE 1A - Phase Loss
Control (Option BF15),
Auto Reset,
3Ph,
P/N 206105
CODE 1B - Phase Loss/Over
and Under Voltage Control
(Option BF14),
Auto Reset, 3Ph,
P/N 176826
Socket, P/N 194168
(not illustrated)
CODE 2 and 14 - Plug-in Relay, Omron
Relay 3PDT, 24VAC, P/N 211799
Socket for 3PDT relay, P/N 211800
Relay, DPDT, LY2-AC24, P/N 211411
Relay, DPDT, LY2-AC110/120, P/N 211412
Relay, DPDT, LY2-AC200/220, P/N 211413
Relay, DPDT, LY2-AC220/240, P/N 211414
Socket for DPDT relays, P/N 211415
CODE 7A - Variable
Frequency Drive
Control (Opt VFD)
and Matching Line
Reactor
CODES 18A
and 18B -
Combustion
Air Pressure
Switches for
Gas-Fired
Models
CODE 6 - Fuse, #Mdq
1-1/2, for DG Options,
P/N 193803
Fuseholder, P/N 60241
CODE 5 - Terminal
Board for Thermostat
with AG Options only,
P/N 164545
Transformers,
CODES 3, 4,
10, and 13
CODE 15 - DSI Integrated
Control Module for PDH/
SDH/SHH/RDH/RHH with
all gas controls except
AG58 or D12G, P/N 195573
(Serial No. Code 78)
PDH/
SDH/
RDH
High Speed for sea level to
6000 ft (1830M) elevation
High Speed for above
6000 ft (1830M) elevation
Low Speed for all elevations
(applies to units with 2-speed
venter only)*
Switch P/N Setting (" w.c.) Switch P/N Setting (" w.c.) Switch P/N Setting (" w.c.)
75
197030
0.4
197031
0.35
205442
0.2
100
197030
0.4
197031
0.35
205444
0.3
125
196388
0.5
197032
0.45
205444
0.3
150
197028
0.65
197029
0.6
205444
0.3
175
201158
1.1
201160
1.05
197030
0.4
200
201158
1.1
201160
1.05
197030
0.4
225
201158
1.1
201160
1.05
197030
0.4
250
201158
1.1
201160
1.05
197030
0.4
300
201158
1.1
201160
1.05
197030
0.4
350
201158
1.1
201160
1.05
197030
0.4
400A
201158
1.1
201160
1.05
197030
0.4
Mtr HP
& Type
VFD Drive and
Matching Line
Reactor
208/1/60
230/1/60
208/3/60 230/3/60
480/3/60
575/3/60
ODP TEFC ODP TEFC Prem ODP TEFC Prem ODP TEFC Prem
1/2 Drive
221600
221605
N/A
221612
N/A
N/A
Line Reactor
221595
221598
221590
3/4 Drive
N/A
221606
N/A
221613
N/A
N/A
Line Reactor
221598
221591
1
Drive
221601
221607
221614
N/A
Line Reactor
221596
221594
221592
1-1/2 Drive
221602
221608
221615
N/A
Line Reactor
221597
221595
221593
2
Drive
221603
221609
221616
221855
Line Reactor
221597
221596
221585
NA (Built-in)
3
Drive
221604
221610
221617
221856
Line Reactor
221599
221597
221586
NA (Built-in)
5
Drive
N/A
221611
221618
221857
Line Reactor
221599
221587
NA (Built-in)
NOTE: Blower off delay DIP
switches to be adjusted to
45 seconds for makeup air
applications. Refer to the table
on the control for the settings.
Volts In
Volts Out VA
P/N
115
24
40
194808
208/230
24
40
194536
120/208/240/480
24
75
208989
460/575
230
200
210862
460/575
230
350
210863
CODE 9 - Air
Proving Switch,
0.10” w.c.,
P/N 234712
CODE 8 - Dirty Filter
Switch, P/N 105507
Code 15B - ID Plugs for Models RHH & SHH with
Serial No. Ignition Code 99 (P/N 260917)
ID Plug
P/N
ID Plug
Label
Heat Size
Gas
258101 SHH 130NG
130
Natural
258102 SHH 130LP
Propane
258103 SHH 180NG
180
Natural
258104 SHH 180LP
Propane
258105 SHH 260NG
260
Natural
258106 SHH 260LP
Propane
258107 SHH 350NG
350
Natural
258108 SHH 350LP
Propane
CODE 15 - DSI Integrated Control Module for SHH & RHH w/gas control Opt
AG58 or D12G, Varidigm VB1200-5-RZNR-SHH, P/N 260917 (Serial No. Code 99)
CODE 15B -
ID Plug only
CODE
15A -
Fuse
Only,
P/N
201685
CODE 15 - DSI Integrated Control Module for RDH with
gas control Opt AG58 or D12G, Varidigm VB1200-2-
RZNR-PVA, P/N 260252 (Serial No. Code 98)
Code 15B - ID Plugs for Model RDH w/Ignition CODE 98 (P/N 260252)
ID Plug P/N
ID Plug Label
Heat Section
Gas
258081
PREEVA 175NG
175
Natural
258082
PREEVA 175LP
Propane
258083
PREEVA 200NG
200
Natural
258084
PREEVA 200LP
Propane
258085
PREEVA 225NG
225
Natural
258086
PREEVA 225LP
Propane
258087
PREEVA 250NG
250
Natural
258088
PREEVA 250LP
Propane
258089
PREEVA 300NG
300
Natural
258090
PREEVA 300LP
Propane
258091
PREEVA 350NG
350
Natural
258092
PREEVA 350LP
Propane
258093
PREEVA 400NG
400
Natural
258094
PREEVA 400LP
Propane
Replacement Display,
ABB Model ACS-CP-A,
P/N 272508
* Gas Control Options AG40, AG60, AG61, AG62, DG1, DG2, DG5, DG6, D12B & D12C.
High Speed
SHH/
RHH
with Options
AG2 or D12F
with Option
AG58 or D12G
Switch
P/N
Setting
(" w.c.)
Switch
P/N
Setting
(" w.c.)
130
201161
1.30
201160
1.05
180
201161
1.30
201160
1.05
260
201159
1.40
201160
1.05
350
221228
2.30
201160
1.05
RDH
with Option AG58 or D12G
Switch P/N
Setting (“w.c.)
175
197029
0.60
200
197078
0.80
225
250
205446
0.70
300
350
400A